CVE-2019-6xxx records
Browse official CVE Program records with vulnerability descriptions, affected products, CVSS scores and source references. Browse by the year and numeric range in each CVE ID; publication and update dates appear on each record.
656 records · Page 4 of 7
A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security v
UpdatedA vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28). A denial of service vulnerability exists in the affected products. The vulnerability could be exploited by an attacker wit
UpdatedA vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All ver
UpdatedA vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All ver
UpdatedA vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F,
UpdatedA vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Par
UpdatedA vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All ver
UpdatedA vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). An attacker with network access to port 10005/tcp of the LOGO! device could cause a Denial-of-Service condition by sending specially crafted packets. The security vulnerability could be exploited
UpdatedA vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Due to insufficient checking of user permissions, an attacker may access URLs that require special authorization. An attacker must have access to a low privileged account in order to exploit the vulnerability.
UpdatedThe monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.
Updated- CVE-2019-6568: The webserver of the affected devices contains a vulnerability that may lead to 7.5 High
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and
Updated A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An atta
UpdatedGE Communicator, all versions prior to 4.0.517, allows a non-administrative user to replace the uninstaller with a malicious version, which could allow an attacker to gain administrator privileges to the system.
UpdatedMoxa IKS and EDS fails to properly validate user input, giving unauthenticated and authenticated attackers the ability to perform XSS attacks, which may be used to send a malicious script.
UpdatedGE Communicator, all versions prior to 4.0.517, allows a non-administrative user to place malicious files within the installer file directory, which may allow an attacker to gain administrative privileges on a system during installation or upgrade.
UpdatedMoxa IKS and EDS generate a predictable cookie calculated with an MD5 hash, allowing an attacker to capture the administrator's password, which could lead to a full compromise of the device.
UpdatedIn Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
UpdatedCross-site request forgery has been identified in Moxa IKS and EDS, which may allow for the execution of unauthorized actions on the device.
UpdatedIn Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak.
UpdatedMoxa IKS and EDS allow remote authenticated users to cause a denial of service via a specially crafted packet, which may cause the switch to crash.
UpdatedIn Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak.
UpdatedSeveral buffer overflow vulnerabilities have been identified in Moxa IKS and EDS, which may allow remote code execution.
UpdatedWhen processing project files, the application (Omron CX-Programmer v9.70 and prior and Common Components January 2019 and prior) fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
UpdatedCscape, 9.80 SP4 and prior. An improper input validation vulnerability may be exploited by processing specially crafted POC files. This may allow an attacker to read confidential information and remotely execute arbitrary code.
UpdatedAdvantech WebAccess/SCADA, Versions 8.3.5 and prior. An improper access control vulnerability may allow an attacker to cause a denial-of-service condition.
UpdatedA vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition.
UpdatedAdvantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution.
UpdatedPangea Communications Internet FAX ATA all Versions 3.1.8 and prior allow an attacker to bypass user authentication using a specially crafted URL to cause the device to reboot, which may be used to cause a continual denial-of-service condition.
UpdatedAdvantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple stack-based buffer overflow vulnerabilities, caused by a lack of proper validation of the length of user-supplied data, may allow remote code execution.
UpdatedAn attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP.
UpdatedGE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
UpdatedDelta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.84 and prior. An out-of-bounds read vulnerability may cause the software to crash due to lacking user input validation for processing project files.
UpdatedGE Communicator, all versions prior to 4.0.517, allows an attacker to place malicious files within the working directory of the program, which may allow an attacker to manipulate widgets and UI elements.
UpdatedAVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. An unauthenticated remote user could use a specially crafted database connection configuration file to execute an arbitrary process on the server machine.
UpdatedGE Communicator, all versions prior to 4.0.517, has a service running with system privileges that may allow an unprivileged user to perform certain administrative actions, which may allow the execution of scheduled scripts with system administrator privileges. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
UpdatedAVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
UpdatedENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated user to initiate a remote reboot, which may be used to cause a denial of service condition.
UpdatedA memory corruption vulnerability has been identified in WECON LeviStudioU version 1.8.56 and prior, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
UpdatedThe Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia
UpdatedSeveral heap-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior have been identified, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
Updated- CVE-2019-6538: Medtronic Conexus Radio Frequency Telemetry Protocol Improper Access Control 9.3 Critical
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia
Updated Multiple stack-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior may be exploited when parsing strings within project files. The process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage these vulnerabilities to execute code under the context of the current process. Mat Po
UpdatedOpening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process.
UpdatedMitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash and disruption to USB communication.
UpdatedThe uncontrolled search path element vulnerability in Gemalto Sentinel UltraPro Client Library ux32w.dll Versions 1.3.0, 1.3.1, and 1.3.2 enables an attacker to load and execute a malicious file.
UpdatedRegisters used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166).
UpdatedPanasonic FPWIN Pro version 7.3.0.0 and prior allows attacker-created project files to be loaded by an authenticated user triggering incompatible type errors because the resource does not have expected properties. This may lead to remote code execution.
UpdatedAn attacker could retrieve passwords from a HTTP GET request from the Kunbus PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) if the attacker is in an MITM position.
UpdatedPanasonic FPWIN Pro version 7.3.0.0 and prior allows attacker-created project files to be loaded by an authenticated user causing heap-based buffer overflows, which may lead to remote code execution.
UpdatedAn attacker could specially craft an FTP request that could crash the PR100088 Modbus gateway versions prior to release R02 (or Software Version 1.1.13166).
UpdatedPSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.
UpdatedPR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted.
UpdatedMoxa IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior use plaintext transmission of sensitive data, which may allow an attacker to capture sensitive data such as an administrative password.
UpdatedAVEVA Wonderware System Platform 2017 Update 2 and prior uses an ArchestrA network user account for authentication of system processes and inter-node communications. A user with low privileges could make use of an API to obtain the credentials for this account.
UpdatedMoxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
UpdatedWebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands.
UpdatedMoxa IKS and EDS fails to properly check array bounds which may allow an attacker to read device memory on arbitrary addresses, and may allow an attacker to retrieve sensitive data or cause device reboot.
UpdatedWebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information.
UpdatedMoxa IKS and EDS does not properly check authority on server side, which results in a read-only user being able to perform arbitrary configuration changes.
UpdatedWebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data.
UpdatedMoxa IKS and EDS store plaintext passwords, which may allow sensitive information to be read by someone with access to the device.
UpdatedBD FACSLyric Research Use Only, Windows 10 Professional Operating System, U.S. and Malaysian Releases, between November 2017 and November 2018 and BD FACSLyric IVD Windows 10 Professional Operating System US release does not properly enforce user access control to privileged accounts, which may allow for unauthorized access to administrative level functions.
UpdatedAn issue was discovered in WSO2 Dashboard Server 2.0.0. It is possible to force the application to perform requests to the internal workstation (port-scanning) and to perform requests to adjacent workstations (network-scanning), aka SSRF.
UpdatedAn issue was discovered in WSO2 API Manager 2.6.0. Uploaded documents for API documentation are available to an unauthenticated user.
UpdatedAn issue was discovered in WSO2 Dashboard Server 2.0.0. It is possible to inject a JavaScript payload that will be stored in the database and then displayed and executed on the same page, aka XSS.
UpdatedAn issue was discovered in WSO2 API Manager 2.6.0. It is possible for a logged-in user to upload, as API documentation, any type of file by changing the extension to an allowed one.
UpdatedAn issue was discovered in WSO2 API Manager 2.6.0. It is possible to force the application to perform requests to the internal workstation (SSRF port-scanning), other adjacent workstations (SSRF network scanning), or to enumerate files because of the existence of the file:// wrapper.
UpdatedAn issue was discovered in creditease-sec insight through 2018-09-11. user_delete in srcpm/app/admin/views.py allows CSRF.
UpdatedAn issue was discovered in creditease-sec insight through 2018-09-11. depart_delete in srcpm/app/admin/views.py allows CSRF.
UpdatedAn issue was discovered in creditease-sec insight through 2018-09-11. role_perm_delete in srcpm/app/admin/views.py allows CSRF.
UpdatedAn issue was discovered in creditease-sec insight through 2018-09-11. login_user_delete in srcpm/app/admin/views.py allows CSRF.
UpdatedSuiteCRM before 7.8.28, 7.9.x and 7.10.x before 7.10.15, and 7.11.x before 7.11.3 allows SQL Injection.
UpdatedInsufficient output sanitization in the Automic Web Interface (AWI), in CA Automic Workload Automation 12.0 to 12.2, allow attackers to potentially conduct persistent cross site scripting (XSS) attacks via a crafted object.
UpdatedThere is a deserialization vulnerability in Chatopera cosin v3.10.0. An attacker can execute commands during server-side deserialization by uploading maliciously constructed files. This is related to the TemplateController.java impsave method and the MainUtils toObject method.
Updatedsc_context_create in ctx.c in libopensc in OpenSC 0.19.0 has a memory leak, as demonstrated by a call from eidenv.
UpdatedIn QEMU 3.1, scsi_handle_inquiry_reply in hw/scsi/scsi-generic.c allows out-of-bounds write and read operations.
UpdatedIn Axway File Transfer Direct 2.7.1, an unauthenticated Directory Traversal vulnerability can be exploited by issuing a specially crafted HTTP GET request with %2e instead of '.' characters, as demonstrated by an initial /h2hdocumentation//%2e%2e/ substring.
UpdatedTeradata Viewpoint before 14.0 and 16.20.00.02-b80 contains a hardcoded password of TDv1i2e3w4 for the viewpoint database account (in viewpoint-portal\conf\server.xml) that could potentially be exploited by malicious users to compromise the affected system.
UpdatedGattLib 0.2 has a stack-based buffer over-read in gattlib_connect in dbus/gattlib.c because strncpy is misused.
UpdatedHotels_Server through 2018-11-05 has SQL Injection via the controller/fetchpwd.php username parameter.
UpdatedThe ThreadX-based firmware on Marvell Avastar Wi-Fi devices, models 88W8787, 88W8797, 88W8801, 88W8897, and 88W8997, allows remote attackers to execute arbitrary code or cause a denial of service (block pool overflow) via malformed Wi-Fi packets during identification of available Wi-Fi networks. Exploitation of the Wi-Fi device can lead to exploitation of the host application processor in some cas
UpdatedIMFForceDelete.sys in IObit Malware Fighter 6.2 allows a low privileged user to send IOCTL 0x8016E000 along with a user defined string to a file; that file will be promptly deleted regardless of access controls.
UpdatedSmartDefragDriver.sys (2.0) in IObit Smart Defrag 6 never frees an executable kernel pool that is allocated with user defined bytes and size when IOCTL 0x9C401CC0 is called. This kernel pointer can be leaked if the kernel pool becomes a "big" pool.
UpdatedSmartDefragDriver.sys (2.0) in IObit Smart Defrag 6 never frees an executable kernel pool that is allocated with user defined bytes and size when IOCTL 0x9C401CC4 is called. This kernel pointer can be leaked if the kernel pool becomes a "big" pool.
UpdatedRISI Gestao de Horarios v3201.09.08 rev.23 allows SQL Injection.
UpdatedCertain Lexmark CX, MX, X, XC, XM, XS, and 6500e devices before 2019-02-11 allow remote attackers to erase stored shortcuts.
UpdatedThe string component in the GNU C Library (aka glibc or libc6) through 2.28, when running on the x32 architecture, incorrectly attempts to use a 64-bit register for size_t in assembly codes, which can lead to a segmentation fault or possibly unspecified other impact, as demonstrated by a crash in __memmove_avx_unaligned_erms in sysdeps/x86_64/multiarch/memmove-vec-unaligned-erms.S during a memcpy.
UpdatedTP-Link WDR Series devices through firmware v3 (such as TL-WDR5620 V3.0) are affected by command injection (after login) leading to remote code execution, because shell metacharacters can be included in the weather get_weather_observe citycode field.
UpdatedGo before 1.10.8 and 1.11.x before 1.11.5 mishandles P-521 and P-384 elliptic curves, which allows attackers to cause a denial of service (CPU consumption) or possibly conduct ECDH private key recovery attacks.
UpdatedCitrix NetScaler Gateway 12.1 before build 50.31, 12.0 before build 60.9, 11.1 before build 60.14, 11.0 before build 72.17, and 10.5 before build 69.5 and Application Delivery Controller (ADC) 12.1 before build 50.31, 12.0 before build 60.9, 11.1 before build 60.14, 11.0 before build 72.17, and 10.5 before build 69.5 allow remote attackers to obtain sensitive plaintext information because of a TLS
UpdatedAbine Blur 7.8.2431 allows remote attackers to conduct "Second-Factor Auth Bypass" attacks by using the "Perform a right-click operation to access a forgotten dev menu to insert user passwords that otherwise would require the user to accept a second-factor request in a mobile app." approach, related to a "Multifactor Auth Bypass, Full Disk Encryption Bypass" issue affecting the Affected Chrome Plu
UpdatedDO NOT USE THIS CANDIDATE NUMBER. Reason: The CNA or individual who requested this candidate did not associate it with any vulnerability during 2019
Updated · Rejected recordDO NOT USE THIS CANDIDATE NUMBER. Reason: The CNA or individual who requested this candidate did not associate it with any vulnerability during 2019
Updated · Rejected recordWith pipelining enabled each incoming query on a TCP connection requires a similar resource allocation to a query received via UDP or via TCP without pipelining enabled. A client using a TCP-pipelined connection to a server could consume more resources than the server has been provisioned to handle. When a TCP connection with a large number of pipelined queries is closed, the load on the server re
Updated- CVE-2019-6476: An error in QNAME minimization code can cause BIND to exit with an assertion failure 5.9 Medium
A defect in code added to support QNAME minimization can cause named to exit with an assertion failure if a forwarder returns a referral rather than resolving the query. This affects BIND versions 9.14.0 up to 9.14.6, and 9.15.0 up to 9.15.4.
Updated Mirror zones are a BIND feature allowing recursive servers to pre-cache zone data provided by other servers. A mirror zone is similar to a zone of type secondary, except that its data is subject to DNSSEC validation before being used in answers, as if it had been looked up via traditional recursion, and when mirror zone data cannot be validated, BIND falls back to using traditional recursion inste
Updated- CVE-2019-6474: A packet containing a malformed DUID can cause the kea-dhcp6 server to terminate 5.7 Medium
A missing check on incoming client requests can be exploited to cause a situation where the Kea server's lease storage contains leases which are rejected as invalid when the server tries to load leases from storage on restart. If the number of such leases exceeds a hard-coded limit in the Kea code, a server trying to restart will conclude that there is a problem with its lease store and give up. V
Updated - CVE-2019-6473: A packet containing a malformed DUID can cause the kea-dhcp6 server to terminate 6.5 Medium
An invalid hostname option can trigger an assertion failure in the Kea DHCPv4 server process (kea-dhcp4), causing the server process to exit. Versions affected: 1.4.0 to 1.5.0, 1.6.0-beta1, and 1.6.0-beta2.
Updated - CVE-2019-6472: A packet containing a malformed DUID can cause the kea-dhcp6 server to terminate 6.5 Medium
A packet containing a malformed DUID can cause the Kea DHCPv6 server process (kea-dhcp6) to exit due to an assertion failure. Versions affected: 1.4.0 to 1.5.0, 1.6.0-beta1, and 1.6.0-beta2.
Updated A race condition which may occur when discarding malformed packets can result in BIND exiting due to a REQUIRE assertion failure in dispatch.c. Versions affected: BIND 9.11.0 -> 9.11.7, 9.12.0 -> 9.12.4-P1, 9.14.0 -> 9.14.2. Also all releases of the BIND 9.13 development branch and version 9.15.0 of the BIND 9.15 development branch and BIND Supported Preview Edition versions 9.11.3-S1 -> 9.11.7-S1
Updated