The D-Link DCS series of Wi-Fi cameras contains a stack-based buffer overflow in alphapd, the camera's web server. The overflow allows a remotely authenticated attacker to execute arbitrary code by providing a long string in the WEPEncryption parameter when requesting wireless.htm. Vulnerable devices include DCS-5009L (1.08.11 and below), DCS-5010L (1.14.09 and below), DCS-5020L (1.15.12 and below
UpdatedAn issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Unlimited physical access to the PLC may lead to a manipulation of SD cards data. SD card manipulation may lead to an authentication bypass opportunity.
UpdatedAn issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be restarted manually via a Linux shell.
UpdatedRed Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that can reference memory after it has been freed.
UpdatedABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface.
UpdatedProcessing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).
UpdatedIn WebAccess/SCADA Versions 8.3.5 and prior, multiple untrusted pointer dereference vulnerabilities may allow a remote attacker to execute arbitrary code.
UpdatedDelta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple out-of-bounds read vulnerabilities may cause information disclosure due to lacking user input validation for processing project files.
UpdatedIn WebAccess/SCADA, Versions 8.3.5 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.
UpdatedRed Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, uses a hard-coded password to encrypt protected files in transit and at rest, which may allow an attacker to access configuration files.
UpdatedIn WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991.
UpdatedIn Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited to affect this product.
UpdatedIn WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.
UpdatedIn WebAccess/SCADA, Versions 8.3.5 and prior, a path traversal vulnerability is caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage this vulnerability to delete files while posing as an administrator.
UpdatedRed Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that causes the program to mishandle pointers.
UpdatedIn WebAccess/SCADA Versions 8.3.5 and prior, an out-of-bounds read vulnerability is caused by a lack of proper validation of user-supplied data. Exploitation of this vulnerability may allow disclosure of information.
UpdatedDelta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap.
UpdatedIn Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
UpdatedA type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attacker to execute remote code. The attacker must have local access to the system. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
UpdatedSICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.
UpdatedRed Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that operates outside of the designated memory area.
UpdatedIn Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.
UpdatedMitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user opens the file, the attacker could read arbitrary files.
UpdatedAn out-of-bounds read vulnerability has been identified in Fuji Electric Alpha7 PC Loader Versions 1.1 and prior, which may crash the system.
UpdatedNREL EnergyPlus, Versions 8.6.0 and possibly prior versions, The application fails to prevent an exception handler from being overwritten with arbitrary code.
UpdatedQuest KACE, all versions prior to version 8.0.x, 8.1.x, and 9.0.x, allows unintentional access to the appliance leveraging functions of the troubleshooting tools located in the administrator user interface.
UpdatedMitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.
UpdatedThe application (Network Configurator for DeviceNet Safety 3.41 and prior) searches for resources by means of an untrusted search path that could execute a malicious .dll file not under the application's direct control and outside the intended directories.
UpdatedIn Rockwell Automation PanelView 5510 (all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later), a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device’s file system.
UpdatedMoxa EDR 810, all versions 5.1 and prior, allows an authenticated attacker to abuse the ping feature to execute unauthorized commands on the router, which may allow an attacker to perform remote code execution.
UpdatedPhilips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled.
UpdatedIn Emerson Ovation OCR400 Controller 3.3.1 and earlier, a stack-based buffer overflow vulnerability in the embedded third-party FTP server involves improper handling of a long file name from the LIST command to the FTP service, which may cause the service to overwrite buffers, leading to remote code execution and escalation of privileges.
UpdatedIn GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms.
UpdatedIn Emerson Ovation OCR400 Controller 3.3.1 and earlier, a heap-based buffer overflow vulnerability in the embedded third-party FTP server involves improper handling of a long command to the FTP service, which may cause memory corruption that halts the controller or leads to remote code execution and escalation of privileges.
Updated- CVE-2019-10964: Medtronic MiniMed 508 and Paradigm Series Insulin Pumps Improper Access Control 7.1 High
Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or i
Updated Moxa EDR 810, all versions 5.1 and prior, allows an unauthenticated attacker to be able to retrieve some log files from the device, which may allow sensitive information disclosure. Log files must have previously been exported by a legitimate user.
UpdatedBD Alaris Gateway versions, 1.0.13,1.1.3 Build 10,1.1.3 MR Build 11,1.1.5, and 1.1.6, The web browser user interface on the Alaris Gateway Workstation does not prevent an attacker with knowledge of the IP address of the Alaris Gateway Workstation terminal to gain access to the status and configuration information of the device.
UpdatedIn Advantech WebAccess HMI Designer Version 2.1.9.23 and prior, processing specially crafted MCR files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, allowing remote code execution.
UpdatedZebra Industrial Printers All Versions, Zebra printers are shipped with unrestricted end-user access to front panel options. If the option to use a passcode to limit the functionality of the front panel is applied, specially crafted packets could be sent over the same network to a port on the printer and the printer will respond with an array of information that includes the front panel passcode f
UpdatedBD Alaris Gateway Workstation Versions, 1.1.3 Build 10, 1.1.3 MR Build 11, 1.2 Build 15, 1.3.0 Build 14, 1.3.1 Build 13, This does not impact the latest firmware Versions 1.3.2 and 1.6.1, Additionally, the following products using software Version 2.3.6 and below, Alaris GS, Alaris GH, Alaris CC, Alaris TIVA, The application does not restrict the upload of malicious files during a firmware update.
UpdatedGeutebruck IP Cameras G-Code(EEC-2xxx), G-Cam(EBC-21xx/EFD-22xx/ETHC-22xx/EWPC-22xx): All versions 1.12.0.25 and prior may allow a remote authenticated attacker with access to network configuration to supply system commands to the server, leading to remote code execution as root.
UpdatedGeutebruck IP Cameras G-Code(EEC-2xxx), G-Cam(EBC-21xx/EFD-22xx/ETHC-22xx/EWPC-22xx): All versions 1.12.0.25 and prior may allow a remote authenticated attacker with access to event configuration to store malicious code on the server, which could later be triggered by a legitimate user resulting in code execution within the user’s browser.
UpdatedGeutebruck IP Cameras G-Code(EEC-2xxx), G-Cam(EBC-21xx/EFD-22xx/ETHC-22xx/EWPC-22xx): All versions 1.12.0.25 and prior may allow a remote authenticated user, using a specially crafted URL command, to execute commands as root.
UpdatedIn Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could a
UpdatedAn attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.
UpdatedABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
UpdatedAn attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.
UpdatedDelta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap.
UpdatedFujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.
UpdatedDelta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple out-of-bounds read vulnerabilities may be exploited, allowing information disclosure due to a lack of user input validation for processing specially crafted project files.
UpdatedFujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X are susceptible to a denial-of-service condition as a result of an overflow of TCP packets, which requires the device to be manually rebooted.
UpdatedDelta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. This may occur because CNCSoft lacks user input validation before copying data from project files onto the stack.
UpdatedAn issue was discovered in Joomla! before 3.9.5. The "refresh list of helpsites" endpoint of com_users lacks access checks, allowing calls from unauthenticated users.
UpdatedAn issue was discovered in Joomla! before 3.9.5. The Media Manager component does not properly sanitize the folder parameter, allowing attackers to act outside the media manager root directory.
UpdatedA vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl.
UpdatedA vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR)
UpdatedA vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges.
UpdatedA vulnerability has been identified in SINEMA Server (All versions < V14.0 SP2 Update 1). Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability could be exploited by an attacker with network access to the affected system. An attacker must have a
UpdatedA vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open
UpdatedA vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is
UpdatedA vulnerability has been identified in SIMATIC TDC CP51M1 (All versions < V1.1.7). An attacker with network access to the device could cause a Denial-of-Service condition by sending a specially crafted UDP packet. The vulnerability affects the UDP communication of the device. The security vulnerability could be exploited without authentication. No user interaction is required to exploit this secur
Updated- CVE-2019-10936: Affected devices improperly handle large amounts of specially crafted UDP packets. 7.5 High
Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
Updated A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14)
UpdatedA vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a va
UpdatedA vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions <= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions < v5.50), Spectrum Power 7 (Corporate User Interface) (All versions <= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricke
UpdatedA vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7U
UpdatedA vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7U
UpdatedA vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software
UpdatedA vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vu
UpdatedA vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with networ
UpdatedA vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). Communication with the device is not encrypted. Data transmitted between the device and the user can be obtained by an attacker in a privileged network position. The security vulnerability can be exploited by an attacker in a privileged network position which allows eavesdropping the communication between the affe
UpdatedA vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises inte
UpdatedA vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.3). The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated project file. No further privileges are required on the target system. The vulnerability could compromi
UpdatedAn attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
UpdatedA vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could b
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this se
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vul
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No us
UpdatedA vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd
UpdatedA vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd
UpdatedA vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd
UpdatedA vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An
UpdatedpubRsaDecryptSignedElementExt in MatrixSSL 4.0.1 Open, as used in Inside Secure TLS Toolkit, has a stack-based buffer overflow during X.509 certificate verification because of missing validation in psRsaDecryptPubExt in crypto/pubkey/rsa_pub.c.
UpdatedIn Symfony before 2.7.51, 2.8.x before 2.8.50, 3.x before 3.4.26, 4.x before 4.1.12, and 4.2.x before 4.2.7, HTTP Methods provided as verbs or using the override header may be treated as trusted input, but they are not validated, possibly causing SQL injection or XSS. This is related to symfony/http-foundation.
UpdatedIn Symfony before 2.8.50, 3.x before 3.4.26, 4.x before 4.1.12, and 4.2.x before 4.2.7, it is possible to cache objects that may contain bad user input. On serialization or unserialization, this could result in the deletion of files that the current user has access to. This is related to symfony/cache and symfony/phpunit-bridge.
UpdatedIn Symfony before 2.7.51, 2.8.x before 2.8.50, 3.x before 3.4.26, 4.x before 4.1.12, and 4.2.x before 4.2.7, a vulnerability would allow an attacker to authenticate as a privileged user on sites with user registration and remember me login functionality enabled. This is related to symfony/security.
UpdatedIn Symfony before 2.7.51, 2.8.x before 2.8.50, 3.x before 3.4.26, 4.x before 4.1.12, and 4.2.x before 4.2.7, when service ids allow user input, this could allow for SQL Injection and remote code execution. This is related to symfony/dependency-injection.
UpdatedIn Symfony before 2.7.51, 2.8.x before 2.8.50, 3.x before 3.4.26, 4.x before 4.1.12, and 4.2.x before 4.2.7, validation messages are not escaped, which can lead to XSS when user input is included. This is related to symfony/framework-bundle.
UpdatedIn Airsonic 10.2.1, RecoverController.java generates passwords via org.apache.commons.lang.RandomStringUtils, which uses java.util.Random internally. This PRNG has a 48-bit seed that can easily be bruteforced, leading to trivial privilege escalation attacks.
UpdatedAirsonic 10.2.1 uses Spring's default remember-me mechanism based on MD5, with a fixed key of airsonic in GlobalSecurityConfig.java. An attacker able to capture cookies might be able to trivially bruteforce offline the passwords of associated users.
UpdatedIn Pallets Jinja before 2.10.1, str.format_map allows a sandbox escape.
UpdatedParsedown before 1.7.2, when safe mode is used and HTML markup is disabled, might allow attackers to execute arbitrary JavaScript code if a script (already running on the affected page) executes the contents of any element with a specific class. This occurs because spaces are permitted in code block infostrings, which interferes with the intended behavior of a single class name beginning with the
UpdatedRoundup 1.6 allows XSS via the URI because frontends/roundup.cgi and roundup/cgi/wsgi_handler.py mishandle 404 errors.
UpdatedIn Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the DCERPC SPOOLSS dissector could crash. This was addressed in epan/dissectors/packet-dcerpc-spoolss.c by adding a boundary check.
UpdatedIn Wireshark 3.0.0, the TSDNS dissector could crash. This was addressed in epan/dissectors/packet-tsdns.c by splitting strings safely.
UpdatedIn Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the LDSS dissector could crash. This was addressed in epan/dissectors/packet-ldss.c by handling file digests properly.
UpdatedIn Wireshark 3.0.0, the Rbm dissector could go into an infinite loop. This was addressed in epan/dissectors/file-rbm.c by handling unknown object types safely.
UpdatedIn Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the SRVLOC dissector could crash. This was addressed in epan/dissectors/packet-srvloc.c by preventing a heap-based buffer under-read.
UpdatedIn Wireshark 3.0.0, the GSUP dissector could go into an infinite loop. This was addressed in epan/dissectors/packet-gsm_gsup.c by rejecting an invalid Information Element length.
UpdatedIn Wireshark 3.0.0, the IEEE 802.11 dissector could go into an infinite loop. This was addressed in epan/dissectors/packet-ieee80211.c by detecting cases in which the bit offset does not advance.
Updated