CVE-2021-22xxx records
Browse official CVE Program records with vulnerability descriptions, affected products, CVSS scores and source references. Browse by the year and numeric range in each CVE ID; publication and update dates appear on each record.
826 records · Page 2 of 9
curl 7.61.0 through 7.76.1 suffers from exposure of data element to wrong session due to a mistake in the code for CURLOPT_SSL_CIPHER_LIST when libcurl is built to use the Schannel TLS library. The selected cipher set was stored in a single "static" variable in the library, which has the surprising side-effect that if an application sets up multiple concurrent transfers, the last one that sets the
UpdatedNextcloud Mail before 1.9.5 suffers from improper access control due to a missing permission check allowing other authenticated users to create mail aliases for other users.
UpdatedNextcloud Desktop Client before 3.3.1 is vulnerable to improper certificate validation due to lack of SSL certificate verification when using the "Register with a Provider" flow.
UpdatedA buffer overflow vulnerability exists in Pulse Connect Secure before 9.1R11.4 allows a remote authenticated attacker to execute arbitrary code as the root user via maliciously crafted meeting room.
UpdatedPulse Connect Secure 9.0R3/9.1R1 and higher is vulnerable to an authentication bypass vulnerability exposed by the Windows File Share Browser and Pulse Secure Collaboration features of Pulse Connect Secure that can allow an unauthenticated user to perform remote arbitrary code execution on the Pulse Connect Secure gateway. This vulnerability has been exploited in the wild.
UpdatedAn information disclosure vulnerability exists in the Rocket.Chat server fixed v3.13, v3.12.2 & v3.11.3 that allowed email addresses to be disclosed by enumeration and validation checks.
UpdatedA missing authorization vulnerability exists in Citrix ShareFile Storage Zones Controller before 5.7.3, 5.8.3, 5.9.3, 5.10.1 and 5.11.18 may allow unauthenticated remote compromise of the Storage Zones Controller.
Updatedcurl 7.63.0 to and including 7.75.0 includes vulnerability that allows a malicious HTTPS proxy to MITM a connection due to bad handling of TLS 1.3 session tickets. When using a HTTPS proxy and TLS 1.3, libcurl can confuse session tickets arriving from the HTTPS proxy but work as if they arrived from the remote server and then wrongly "short-cut" the host handshake. When confusing the tickets, a HT
UpdatedRevive Adserver before v5.2.0 is vulnerable to a reflected XSS vulnerability in the `statsBreakdown` parameter of stats.php (and possibly other scripts) due to single quotes not being escaped. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and pressing a certain key combination to execute injected JavaScrip
UpdatedRevive Adserver before v5.2.0 is vulnerable to a reflected XSS vulnerability in the `status` parameter of campaign-zone-zones.php. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and execute injected JavaScript code.
UpdatedA vulnerability in the BIOS of Pulse Secure (PSA-Series Hardware) models PSA5000 and PSA7000 could allow an attacker to compromise BIOS firmware. This vulnerability can be exploited only as part of an attack chain. Before an attacker can compromise the BIOS, they must exploit the device.
UpdatedRocket.Chat before 3.11, 3.10.5, 3.9.7, 3.8.8 is vulnerable to persistent cross-site scripting (XSS) using nested markdown tags allowing a remote attacker to inject arbitrary JavaScript in a message. This flaw leads to arbitrary file read and RCE on Rocket.Chat desktop app.
UpdatedA possible information disclosure / unintended method execution vulnerability in Action Pack >= 2.0.0 when using the `redirect_to` or `polymorphic_url`helper with untrusted user input.
UpdatedNode.js before 10.24.0, 12.21.0, 14.16.0, and 15.10.0 is vulnerable to DNS rebinding attacks as the whitelist includes “localhost6”. When “localhost6” is not present in /etc/hosts, it is just an ordinary domain that is resolved via DNS, i.e., over network. If the attacker controls the victim's DNS server or can spoof its responses, the DNS rebinding protection can be bypassed by using the “localho
UpdatedNode.js before 10.24.0, 12.21.0, 14.16.0, and 15.10.0 is vulnerable to a denial of service attack when too many connection attempts with an 'unknownProtocol' are established. This leads to a leak of file descriptors. If a file descriptor limit is configured on the system, then the server is unable to accept new connections and prevent the process also from opening, e.g. a file. If no file descript
UpdatedUniFi Protect before v1.17.1 allows an attacker to use spoofed cameras to perform a denial-of-service attack that may cause the UniFi Protect controller to crash.
UpdatedThe Host Authorization middleware in Action Pack before 6.1.2.1, 6.0.3.5 suffers from an open redirect vulnerability. Specially crafted `Host` headers in combination with certain "allowed host" formats can cause the Host Authorization middleware in Action Pack to redirect users to a malicious website. Impacted applications will have allowed hosts with a leading dot. When an allowed host contains a
UpdatedThe PostgreSQL adapter in Active Record before 6.1.2.1, 6.0.3.5, 5.2.4.5 suffers from a regular expression denial of service (REDoS) vulnerability. Carefully crafted input can cause the input validation in the `money` type of the PostgreSQL adapter in Active Record to spend too much time in a regular expression, resulting in the potential for a DoS attack. This only impacts Rails applications that
UpdatedNextcloud Desktop Client prior to 3.1.3 is vulnerable to resource injection by way of missing validation of URLs, allowing a malicious server to execute remote commands. User interaction is needed for exploitation.
UpdatedNextcloud Server prior to 20.0.6 is vulnerable to reflected cross-site scripting (XSS) due to lack of sanitization in `OC.Notification.show`.
UpdatedA missing user check in Nextcloud prior to 20.0.6 inadvertently populates a user's own credentials for other users external storage configuration when not already configured yet.
Updatedcurl 7.1.1 to and including 7.75.0 is vulnerable to an "Exposure of Private Personal Information to an Unauthorized Actor" by leaking credentials in the HTTP Referer: header. libcurl does not strip off user credentials from the URL when automatically populating the Referer: HTTP request header field in outgoing HTTP requests, and therefore risks leaking sensitive data to the server that is the tar
UpdatedRevive Adserver before 5.1.1 is vulnerable to a reflected XSS vulnerability in stats.php via the `setPerPage` parameter.
UpdatedRevive Adserver before 5.1.1 is vulnerable to a reflected XSS vulnerability in userlog-index.php via the `period_preset` parameter.
UpdatedRevive Adserver before 5.1.0 is vulnerable to open redirects via the `dest`, `oadest`, and/or `ct0` parameters of the lg.php and ck.php delivery scripts. Such open redirects had previously been available by design to allow third party ad servers to track such metrics when delivering ads. However, third party click tracking via redirects is not a viable option anymore, leading to such open redirect
UpdatedRevive Adserver before 5.1.0 is vulnerable to a reflected cross-site scripting (XSS) vulnerability via the publicly accessible afr.php delivery script. While this issue was previously addressed in modern browsers as CVE-2020-8115, some older browsers (e.g., IE10) that do not automatically URL encode parameters were still vulnerable.
UpdatedRevive Adserver before 5.1.0 permits any user with a manager account to store possibly malicious content in the URL website property, which is then displayed unsanitized in the affiliate-preview.php tag generation screen, leading to a persistent cross-site scripting (XSS) vulnerability.
UpdatedA path traversal vulnerability was identified in GitHub Pages builds on GitHub Enterprise Server that could allow an attacker to read system files. To exploit this vulnerability, an attacker would need permission to create and build a GitHub Pages site on the GitHub Enterprise Server instance. This vulnerability affected all versions of GitHub Enterprise Server prior to 3.3 and was fixed in versio
UpdatedAn improper access control vulnerability in GitHub Enterprise Server allowed a workflow job to execute in a self-hosted runner group it should not have had access to. This affects customers using self-hosted runner groups for access control. A repository with access to one enterprise runner group could access all of the enterprise runner groups within the organization because of improper authentic
UpdatedA path traversal vulnerability was identified in GitHub Enterprise Server that could be exploited when building a GitHub Pages site. User-controlled configuration options used by GitHub Pages were not sufficiently restricted and made it possible to read files on the GitHub Enterprise Server instance. To exploit this vulnerability, an attacker would need permission to create and build a GitHub Page
UpdatedA path traversal vulnerability was identified in GitHub Enterprise Server that could be exploited when building a GitHub Pages site. User-controlled configuration options used by GitHub Pages were not sufficiently restricted and made it possible to read files on the GitHub Enterprise Server instance. To exploit this vulnerability, an attacker would need permission to create and build a GitHub Page
UpdatedA UI misrepresentation vulnerability was identified in GitHub Enterprise Server that allowed more permissions to be granted during a GitHub App's user-authorization web flow than was displayed to the user during approval. To exploit this vulnerability, an attacker would need to create a GitHub App on the instance and have a user authorize the application through the web authentication flow. All pe
UpdatedAn improper access control vulnerability was identified in GitHub Enterprise Server that allowed access tokens generated from a GitHub App's web authentication flow to read private repository metadata via the REST API without having been granted the appropriate permissions. To exploit this vulnerability, an attacker would need to create a GitHub App on the instance and have a user authorize the ap
UpdatedA remote code execution vulnerability was identified in GitHub Enterprise Server that could be exploited when building a GitHub Pages site. User-controlled configuration options used by GitHub Pages were not sufficiently restricted and made it possible to override environment variables leading to code execution on the GitHub Enterprise Server instance. To exploit this vulnerability, an attacker wo
UpdatedAn improper access control vulnerability was identified in the GitHub Enterprise Server GraphQL API that allowed authenticated users of the instance to modify the maintainer collaboration permission of a pull request without proper authorization. By exploiting this vulnerability, an attacker would be able to gain access to head branches of pull requests opened on repositories of which they are a m
UpdatedAn improper access control vulnerability was identified in GitHub Enterprise Server that allowed an authenticated user with the ability to fork a repository to disclose Actions secrets for the parent repository of the fork. This vulnerability existed due to a flaw that allowed the base reference of a pull request to be updated to point to an arbitrary SHA or another pull request outside of the for
UpdatedAn improper access control vulnerability was identified in GitHub Enterprise Server that allowed authenticated users of the instance to gain write access to unauthorized repositories via specifically crafted pull requests and REST API requests. An attacker would need to be able to fork the targeted repository, a setting that is disabled by default for organization owned private repositories. Branc
UpdatedEIC e-document system does not perform completed identity verification for sorting and filtering personnel data. The vulnerability allows remote attacker to obtain users’ credential information without logging in the system, and further acquire the privileged permissions and execute arbitrary commends.
UpdatedThe users’ data querying function of EIC e-document system does not filter the special characters which resulted in remote attackers can inject SQL syntax and execute arbitrary commands without privilege.
Updated- CVE-2021-22858: ChanGate EnterPrise Co., Ltd property management system - Broken Authentication 8.8 High
Attackers can access the CGE account management function without privilege for permission elevation and execute arbitrary commands or files after obtaining user permissions.
Updated - CVE-2021-22857: ChanGate EnterPrise Co., Ltd property management system - Directory Traversal 7.5 High
The CGE page with download function contains a Directory Traversal vulnerability. Attackers can use this loophole to download system files arbitrarily.
Updated - CVE-2021-22856: ChanGate EnterPrise Co., Ltd property management system - SQL Injection 9.8 Critical
The CGE property management system contains SQL Injection vulnerabilities. Remote attackers can inject SQL commands into the parameters in Cookie and obtain data in the database without privilege.
Updated The specific function of HR Portal of Soar Cloud System accepts any type of object to be deserialized. Attackers can send malicious serialized objects to execute arbitrary commands.
UpdatedThe HR Portal of Soar Cloud System fails to filter specific parameters. Remote attackers can inject SQL syntax and obtain all data in the database without privilege.
UpdatedThe HR Portal of Soar Cloud System fails to manage access control. While obtaining user ID, remote attackers can access sensitive data via a specific data packet, such as user’s login information, further causing the login function not to work.
UpdatedHGiga EIP product contains SQL Injection vulnerability. Attackers can inject SQL commands into specific URL parameter (online registration) to obtain database schema and data.
UpdatedHGiga EIP product contains SQL Injection vulnerability. Attackers can inject SQL commands into specific URL parameter (document management page) to obtain database schema and data.
UpdatedHGiga EIP product lacks ineffective access control in certain pages that allow attackers to access database or perform privileged functions.
Updated- CVE-2021-22849: Hyweb HyCMS-J1 - Stored XSS 4.6 Medium
Hyweb HyCMS-J1 backend editing function does not filter special characters. Users after log-in can inject JavaScript syntax to perform a stored XSS (Stored Cross-site scripting) attack.
Updated HGiga MailSherlock contains a SQL Injection. Remote attackers can inject SQL syntax and execute SQL commands in a URL parameter of email pages without privilege.
UpdatedHyweb HyCMS-J1's API fail to filter POST request parameters. Remote attackers can inject SQL syntax and execute commands without privilege.
UpdatedA CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions
UpdatedA CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions
UpdatedA CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V
UpdatedA CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
UpdatedA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
UpdatedA CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8
UpdatedA CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2
UpdatedA CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions pri
UpdatedA CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0
UpdatedA CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart W
UpdatedA CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)
UpdatedA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E RTUs with firmware V8.18.1 and prior
UpdatedA CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power
UpdatedA CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP
UpdatedA CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 w
UpdatedA CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (N
UpdatedA CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2):
UpdatedA CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500
UpdatedA CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
UpdatedA CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
UpdatedA CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
UpdatedA CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)
UpdatedA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
UpdatedA CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
UpdatedA CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
UpdatedA CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
UpdatedA CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially crafted event actions. Affected Product: ConneXium Network Manager Software (All Versions)
UpdatedA CWE-20: Improper Input Validation vulnerability exists that could cause a Denial of Service when a crafted packet is sent to the controller over network port 1105/TCP. Affected Product: Modicon M218 Logic Controller (V5.1.0.6 and prior)
UpdatedA CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1
UpdatedA CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions)
UpdatedA CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including form
UpdatedA CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
UpdatedA CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
UpdatedA CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
UpdatedA CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.
UpdatedA CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momen
UpdatedA CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum E
UpdatedA CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Et
UpdatedA CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (par
UpdatedA CWE-787: Out-of-bounds Write vulnerability exists that could cause denial of service when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors w
UpdatedA CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon P
UpdatedA CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V
UpdatedA CWE-200: Information Exposure vulnerability exists that could cause sensitive information of files located in the web root directory to leak when an attacker sends a HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All V
UpdatedA CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system.
UpdatedA CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions)
UpdatedMissing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, cre
UpdatedInsufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can
UpdatedInsufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is
UpdatedAuthentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*),
Updated