CVE-2020-25xxx records
Browse official CVE Program records with vulnerability descriptions, affected products, CVSS scores and source references. Browse by the year and numeric range in each CVE ID; publication and update dates appear on each record.
629 records · Page 5 of 7
An issue was discovered in InspIRCd 2 before 2.0.29 and 3 before 3.6.0. The pgsql module contains a use after free vulnerability. When combined with the sqlauth or sqloper modules, this vulnerability can be used for remote crashing of an InspIRCd server by any user able to connect to a server.
UpdatedRemote Code Execution can occur via the external news feed in ILIAS 6.4 because of incorrect parameter sanitization for Magpie RSS data.
Updated- CVE-2020-25267: An XSS issue exists in the question-pool file-upload preview feature in ILIAS 6.4. Unscored
An XSS issue exists in the question-pool file-upload preview feature in ILIAS 6.4.
Updated AppImage appimaged before 1.0.3 does not properly check whether a downloaded file is a valid appimage. For example, it will accept a crafted mp3 file that contains an appimage, and install it.
UpdatedAppImage libappimage before 1.0.3 allows attackers to trigger an overwrite of a system-installed .desktop file by providing a .desktop file that contains Name= with path components.
UpdatedPyroCMS 3.7 is vulnerable to cross-site request forgery (CSRF) via the admin/addons/uninstall/anomaly.module.blocks URI: an arbitrary plugin will be deleted.
UpdatedPyroCMS 3.7 is vulnerable to cross-site request forgery (CSRF) via the admin/pages/delete/ URI: pages will be deleted.
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. It allows remote attackers to execute arbitrary code because of unsafe JSON deserialization.
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. It uses XML deserialization libraries in an unsafe manner.
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. It uses ASP.NET BinaryFormatter.Deserialize in a manner that allows attackers to transmit and execute bytecode in SOAP messages.
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. It allows XXE attacks for read/write access to arbitrary files.
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. PKI certificates have a private key that is the same across different customers' installations.
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. It allows remote attackers to cause a denial of service (outage of connection-request processing) via a long user ID, which triggers an exception and a large log entry.
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. It allows SQL injection, as demonstrated by TestConnection_LocalOrLinkedServer, CreateFilterFriendlyView, or AddWorkViewLinkedServer.
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. It allows SQL injection, as demonstrated by the TableName, ColumnName, Name, UserId, or Password parameter.
UpdatedAn issue was discovered in Hyland OnBase through 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. CSRF can be used to log in a user, and then perform actions, because there are default credentials (the wstinol password for the manager or hsi account).
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. Client-side authentication is used for critical functions such as adding users or retrieving sensitive information.
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. Client applications can write arbitrary data to the server logs.
UpdatedAn issue was discovered in Hyland OnBase 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. The server typically logs activity only when a client application specifies that logging is desired. This can be problematic for use cases in a regulated industry, where server-side logging is required in additional situations.
UpdatedAn issue was discovered in Hyland OnBase through 16.0.2.83 and below, 17.0.2.109 and below, 18.0.0.37 and below, 19.8.16.1000 and below and 20.3.10.1000 and below. Directory traversal exists for reading files, as demonstrated by the FileName parameter.
UpdatedAn issue was discovered in Hyland OnBase through 18.0.0.32 and 19.x through 19.8.9.1000. Directory traversal exists for writing to files, as demonstrated by the FileName parameter.
UpdatedA vulnerability has been identified in DIGSI 4 (All versions < V4.94 SP1 HF 1). Several folders in the %PATH% are writeable by normal users. As these folders are included in the search for dlls, an attacker could place dlls there with code executed by SYSTEM.
UpdatedA vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.4). The software insecurely loads libraries which makes it vulnerable to DLL hijacking. Successful exploitation by a local attacker could lead to a takeover of the system where the software is installed.
UpdatedA vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.4). A zip slip vulnerability could be triggered while importing a compromised project file to the affected software. Chained with other vulnerabilities this vulnerability could ultimately lead to a system takeover by an attacker.
UpdatedA vulnerability has been identified in SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions). Specially crafted packets sent to TCP port 102 could cause a Denial-of-Service condition on the affected devices. A cold restart might be necessary in orde
UpdatedA vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). The underlying TCP stack of the affected products does not correctly validate the sequence number for incoming TCP RST packages. An attacker could exploit this to terminate arbitrary TCP sessions.
UpdatedA vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service.
UpdatedA vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights.
UpdatedA vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.
UpdatedA vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1 Update 1), SINEMA Server (All versions < V14.0 SP2 Update 2). When uploading files to an affected system using a zip container, the system does not correctly check if the relative file path of the extracted files is still within the intended target directory. With this an attacker could create or overwrite arbitrary files on
UpdatedA vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24R
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The password used for authentication for the LOGO! Website and the LOGO! Access Tool is sent in a recoverable format. An attacker with access to the network traffic could derive valid logins.
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The LOGO! program files generated and used by the affected components offer the possibility to save user-defined functions (UDF) in a password protected way. This protection is implemented in the software that displays the information. An attacker could reverse
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The firmware update of affected devices contains the private RSA key that is used as a basis for encryption of communication with the device.
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port 8080/tcp.
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program files.
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an outdated cipher mode on port 10005/tcp, an attacker could extract the encryption key from a captured communication with the device.
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any affected device if using prepared messages that were generated for another device.
UpdatedA vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port.
UpdatedA vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially craft
UpdatedA remote code execution vulnerability exists in the WebAdmin of Sophos SG UTM before v9.705 MR5, v9.607 MR7, and v9.511 MR11
Updatedget_gate_page in mm/gup.c in the Linux kernel 5.7.x and 5.8.x before 5.8.7 allows privilege escalation because of incorrect reference counting (caused by gate page mishandling) of the struct page that backs the vsyscall page. The result is a refcount underflow. This can be triggered by any 64-bit process that can use ptrace() or process_vm_readv(), aka CID-9fa2dd946743.
UpdatedThe Linux kernel 4.9.x before 4.9.233, 4.14.x before 4.14.194, and 4.19.x before 4.19.140 has a use-after-free because skcd->no_refcnt was not considered during a backport of a CVE-2020-14356 patch. This is related to the cgroups feature.
Updatedurl::recvline in url.cpp in libproxy 0.4.x through 0.4.15 allows a remote HTTP server to trigger uncontrolled recursion via a response composed of an infinite stream that lacks a newline character. This leads to stack exhaustion.
UpdatedGrandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allow Authentication Bypass in its administrative web interface.
UpdatedGrandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allows Command Injection as root in its administrative web interface.
UpdatedyWorks yEd Desktop before 3.20.1 allows code execution via an XSL Transformation when using an XML file in conjunction with a custom stylesheet.
Updated- CVE-2020-25215: yWorks yEd Desktop before 3.20.1 allows XXE attacks via an XML or GraphML document. Unscored
yWorks yEd Desktop before 3.20.1 allows XXE attacks via an XML or GraphML document.
Updated In the client in Overwolf 0.149.2.30, a channel can be accessed or influenced by an actor that is not an endpoint.
UpdatedThe File Manager (wp-file-manager) plugin before 6.9 for WordPress allows remote attackers to upload and execute arbitrary PHP code because it renames an unsafe example elFinder connector file to have the .php extension. This, for example, allows attackers to run the elFinder upload (or mkfile and put) command to write PHP code into the wp-content/plugins/wp-file-manager/lib/files/ directory. This
UpdatedA TOCTOU mismatch in the NFS client code in the Linux kernel before 5.8.3 could be used by local attackers to corrupt memory or possibly have unspecified other impact because a size check is in fs/nfs/nfs4proc.c instead of fs/nfs/nfs4xdr.c, aka CID-b4487b935452.
UpdatedIn the Linux kernel through 5.8.7, local attackers able to inject conntrack netlink configuration could overflow a local buffer, causing crashes or triggering use of incorrect protocol numbers in ctnetlink_parse_tuple_filter in net/netfilter/nf_conntrack_netlink.c, aka CID-1cc5ef91d2ff.
UpdatedIn JetBrains YouTrack before 2020.3.7955, an attacker could access workflow rules without appropriate access grants.
UpdatedIn JetBrains YouTrack before 2020.3.6638, improper access control for some subresources leads to information disclosure via the REST API.
UpdatedIn JetBrains YouTrack before 2020.4.4701, an attacker could enumerate users via the REST API without appropriate permissions.
UpdatedJetBrains ToolBox before version 1.18 is vulnerable to Remote Code Execution via a browser protocol handler.
UpdatedThe web console for Mimosa B5, B5c, and C5x firmware through 2.8.0.2 allows authenticated command injection in the Throughput, WANStats, PhyStats, and QosStats API classes. An attacker with access to a web console account may execute operating system commands on affected devices by sending crafted POST requests to the affected endpoints (/core/api/calls/Throughput.php, /core/api/calls/WANStats.php
UpdatedThe web console for Mimosa B5, B5c, and C5x firmware through 2.8.0.2 is vulnerable to stored XSS in the set_banner() function of /var/www/core/controller/index.php. An unauthenticated attacker may set the contents of the /mnt/jffs2/banner.txt file, stored on the device's filesystem, to contain arbitrary JavaScript. The file contents are then used as part of a welcome/banner message presented to un
UpdatedThe God Kings application 0.60.1 for Android exposes a broadcast receiver to other apps called com.innogames.core.frontend.notifications.receivers.LocalNotificationBroadcastReceiver. The purpose of this broadcast receiver is to show an in-game push notification to the player. However, the application does not enforce any authorization schema on the broadcast receiver, allowing any application to s
UpdatedThe Framer Preview application 12 for Android exposes com.framer.viewer.FramerViewActivity to other applications. By calling the intent with the action set to android.intent.action.VIEW, any other application is able to load any website/web content into the application's context, which is shown as a full-screen overlay to the user.
UpdatedHashiCorp Consul Enterprise version 1.7.0 up to 1.8.4 includes a namespace replication bug which can be triggered to cause denial of service via infinite Raft writes. Fixed in 1.7.9 and 1.8.5.
UpdatedPritunl 1.29.2145.25 allows attackers to enumerate valid VPN usernames via a series of /auth/session login attempts. Initially, the server will return error 401. However, if the username is valid, then after 20 login attempts, the server will start responding with error 400. Invalid usernames will receive error 401 indefinitely. Note: This has been disputed by the vendor as not a vulnerability. Th
UpdatedA heap-based buffer overflow vulnerability exists within the WECON LeviStudioU Release Build 2019-09-21 and prior when processing project files. Opening a specially crafted project file could allow an attacker to exploit and execute code under the privileges of the application.
UpdatedThe built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user’s cookies.
UpdatedA code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system.
Updated- CVE-2020-25196: MOXA NPort IAW5000A-I/O Series 9.8 Critical
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication.
Updated The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device.
UpdatedThe built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges.
UpdatedBy having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection.
UpdatedThe built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization.
UpdatedIncorrect permissions are set by default for an API entry-point of a specific service, allowing a non-authenticated user to trigger a function that could reboot the CompactRIO (Driver versions prior to 20.5) remotely.
UpdatedThe built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext.
UpdatedThe affected product is vulnerable to three stack-based buffer overflows, which may allow an unauthenticated attacker to remotely execute arbitrary code on the IP150 (firmware versions 5.02.09).
UpdatedAn attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the application due to an out-of-bounds read vulnerability on the LAquis SCADA (Versions prior to 4.3.1.870).
UpdatedMedtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the MCL Smart Patient Reader, potentially leading to control of the device
UpdatedAn XXE vulnerability exists within LeviStudioU Release Build 2019-09-21 and prior when processing parameter entities, which may allow file disclosure.
UpdatedThe affected product is vulnerable to five post-authentication buffer overflows, which may allow a logged in user to remotely execute arbitrary code on the IP150 (firmware versions 5.02.09).
UpdatedRockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
UpdatedMedtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart
UpdatedRockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
UpdatedWECON PLC Editor Versions 1.3.8 and prior has a heap-based buffer overflow vulnerabilities have been identified that may allow arbitrary code execution.
UpdatedRockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypte
UpdatedGE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
Updated- CVE-2020-25178: Rockwell Automation ISaGRAF5 Runtime Cleartext Transmission of Sensitive Information 7.5 High
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.
Updated WECON PLC Editor Versions 1.3.8 and prior has a stack-based buffer overflow vulnerability has been identified that may allow arbitrary code execution.
UpdatedSome commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.
UpdatedGE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
Updated- CVE-2020-25174: B. Braun OnlineSuite Unscored
A DLL hijacking vulnerability in the B. Braun OnlineSuite Version AP 3.0 and earlier allows local attackers to execute code on the system as a high privileged user.
Updated - CVE-2020-25173: Reolink P2P Cameras Unscored
An attacker with local network access can obtain a fixed cryptography key which may allow for further compromise of Reolink P2P cameras outside of local network access
Updated - CVE-2020-25172: B. Braun OnlineSuite Unscored
A relative path traversal attack in the B. Braun OnlineSuite Version AP 3.0 and earlier allows unauthenticated attackers to upload or download arbitrary files.
Updated The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.
Updated- CVE-2020-25170: B. Braun OnlineSuite Unscored
An Excel Macro Injection vulnerability exists in the export feature in the B. Braun OnlineSuite Version AP 3.0 and earlier via multiple input fields that are mishandled in an Excel export.
Updated - CVE-2020-25169: Reolink P2P Cameras Unscored
The affected Reolink P2P products do not sufficiently protect data transferred between the local device and Reolink servers. This can allow an attacker to access sensitive information, such as camera feeds.
Updated Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module.
UpdatedOSIsoft PI Vision 2020 versions prior to 3.5.0 could disclose information to a user with insufficient privileges for an AF attribute.
UpdatedAn improper verification of the cryptographic signature of firmware updates of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to generate valid firmware updates with arbitrary content that can be used to tamper with devices.
UpdatedBD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier The affected products are vulnerable to a network session authentication vulnerability within the authentication process between specified versions of the BD Alaris PC Unit and the BD Alaris Systems Manager. If exploited, an attacker could perform a denial-of-service attack on the BD
Updated- CVE-2020-25164: B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus 6.5 Medium
A vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to recover user credentials of the administrative interface.
Updated A remote attacker with write access to PI ProcessBook files could inject code that is imported into OSIsoft PI Vision 2020 versions prior to 3.5.0. Unauthorized information disclosure, modification, or deletion is also possible if a victim views or interacts with the infected display. This vulnerability affects PI System data and other data accessible with victim’s user permissions.
UpdatedA XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges.
Updated