Description
gonic versions before 0.22.0 fail to validate administrator privileges in the startScan endpoint, allowing any authenticated user to trigger media library rescans. Attackers can repeatedly call the startScan endpoint to force CPU and I/O-intensive filesystem operations, causing denial of service on multi-user instances.
Affected products
Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.
sentriz gonic
Default version status: unaffected
0 to < 0.22.0affected
pkg:golang/go.senan.xyz/gonicReferences
- https://github.com/sentriz/gonic/security/advisories/GHSA-453r-pgfw-h3pq ↗
- https://github.com/sentriz/gonic/blob/v0.21.0/server/ctrlsubsonic/handlers_common.go ↗
- https://github.com/sentriz/gonic/blob/v0.21.0/server/ctrlsubsonic/ctrl.go ↗
- https://github.com/sentriz/gonic/releases/tag/v0.22.0 ↗
- https://github.com/sentriz/gonic ↗