Skip to content
CVE PROGRAM SOURCE RECORD8.6 High

CVE-2026-82017

IGEL OS 12 / 11 Boot Registry Parameter Injection via Unsigned Configuration Area

Description

IGEL OS 12 before 12.7.6 and IGEL OS 11 before 11.11.150 contain a boot registry parameter injection vulnerability that allows attackers with physical access to execute arbitrary Linux loader parameters by writing to an unencrypted and unsigned configuration area read by the signed bootloader. Attackers can inject malicious kernel command line parameters that execute with boot environment privileges without triggering TPM PCR measurement failures, as the attack does not modify the measured boot code.

Affected products

Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.

IGEL IGEL OS 12

Default version status: affected

  • 12.0.0 to < 12.7.6affected

IGEL IGEL OS 11

Default version status: affected

  • 11.0.0 to < 11.11.150affected