Description
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 3.0 TL3-60.0 TL3 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet gridsave 110 TL3-S (All versions < V3.91), blueplanet gridsave 137 TL3-S (All versions < V3.91), blueplanet gridsave 92.0 TL3-S (All versions < V3.91). A CRC16-based algorithm for generating Technical Service credentials could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access.
Affected products
Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.
Siemens blueplanet 100 NX3 M8
Default version status: unknown
0 to < *affected
Siemens blueplanet 100 TL3 GEN2
Default version status: unknown
0 to < V6.1.4.9affected
Siemens blueplanet 105 TL3
Default version status: unknown
0 to < V3.92affected
Siemens blueplanet 105 TL3 GEN2
Default version status: unknown
0 to < V6.1.4.9affected
Siemens blueplanet 110 TL3
Default version status: unknown
0 to < V3.92affected
Siemens blueplanet 125 NX3 M10
Default version status: unknown
0 to < *affected
Siemens blueplanet 125 TL3
Default version status: unknown
0 to < V3.92affected
Siemens blueplanet 125 TL3 GEN2
Default version status: unknown
0 to < V6.1.4.9affected
Siemens blueplanet 137 TL3
Default version status: unknown
0 to < V3.92affected
Siemens blueplanet 150 TL3
Default version status: unknown
0 to < V3.92affected
Siemens blueplanet 150 TL3 GEN2
Default version status: unknown
0 to < V6.1.4.9affected
Siemens blueplanet 155 TL3
Default version status: unknown
0 to < V3.92affected
Siemens blueplanet 155 TL3 GEN2
Default version status: unknown
0 to < V6.1.4.9affected
Siemens blueplanet 165 TL3
Default version status: unknown
0 to < V3.92affected
Siemens blueplanet 165 TL3 GEN2
Default version status: unknown
0 to < V6.1.4.9affected
Siemens blueplanet 25.0 NX3-33.0 NX3
Default version status: unknown
0 to < *unaffected
Siemens blueplanet 3.0 NX3-20.0 NX3
Default version status: unknown
0 to < *unaffected
Siemens blueplanet 3.0 TL3-60.0 TL3
Default version status: unknown
0 to < *affected
Siemens blueplanet 3.0-5.0 NX1
Default version status: unknown
0 to < *unaffected
Siemens blueplanet 360 NX3 M6
Default version status: unknown
0 to < *unaffected
Siemens blueplanet 50.0 NX3-60.0 NX3
Default version status: unknown
0 to < *unaffected
Siemens blueplanet 87.0 TL3
Default version status: unknown
0 to < V3.92affected
Siemens blueplanet 87.0 TL3 GEN2
Default version status: unknown
0 to < V6.1.4.9affected
Siemens blueplanet 92.0 TL3
Default version status: unknown
0 to < V3.92affected
Siemens blueplanet 92.0 TL3 GEN2
Default version status: unknown
0 to < V6.1.4.9affected
Siemens blueplanet gridsave 110 TL3-S
Default version status: unknown
0 to < V3.91affected
Siemens blueplanet gridsave 137 TL3-S
Default version status: unknown
0 to < V3.91affected
Siemens blueplanet gridsave 92.0 TL3-S
Default version status: unknown
0 to < V3.91affected
Siemens blueplanet hybrid 10.0 TL3
Default version status: unknown
0 to < *unaffected
Siemens blueplanet hybrid 6.0 NH3-12.0 NH3
Default version status: unknown
0 to < *unaffected