Skip to content
CVE PROGRAM SOURCE RECORD5.3 Medium

CVE-2025-40935

A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.1), RUGGEDCOM RS416v2 V5.X (All versions < V5.

Description

A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.1), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.1), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.1), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.1), RUGGEDCOM RSG907R (All versions < V5.10.1), RUGGEDCOM RSG908C (All versions < V5.10.1), RUGGEDCOM RSG909R (All versions < V5.10.1), RUGGEDCOM RSG910C (All versions < V5.10.1), RUGGEDCOM RSG920P V5.X (All versions < V5.10.1), RUGGEDCOM RSL910 (All versions < V5.10.1), RUGGEDCOM RST2228 (All versions < V5.10.1), RUGGEDCOM RST2228P (All versions < V5.10.1), RUGGEDCOM RST916C (All versions < V5.10.1), RUGGEDCOM RST916P (All versions < V5.10.1). Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device.

Affected products

Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.

Siemens RUGGEDCOM RMC8388 V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RS416Pv2 V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RS416v2 V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RS900 (32M) V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RS900G (32M) V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG2100 (32M) V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG2100P (32M) V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG2288 V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG2300 V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG2300P V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG2488 V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG907R

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG908C

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG909R

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG910C

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSG920P V5.X

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RSL910

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RST2228

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RST2228P

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RST916C

Default version status: unknown

  • 0 to < V5.10.1affected

Siemens RUGGEDCOM RST916P

Default version status: unknown

  • 0 to < V5.10.1affected

References