Description
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
Affected products
Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.
Siemens Automation License Manager V6.0
Default version status: unknown
0 to < *affected
Siemens Automation License Manager V6.2
Default version status: unknown
0 to < V6.2 Upd3affected
Siemens CEMAT V10.0
Default version status: unknown
0 to < *affected
Siemens CP PtP Param configuring interface
Default version status: unknown
0 to < *affected
Siemens Create MyConfig (CMC)
Default version status: unknown
0 to < V6.9affected
Siemens Energy Support Library (EnSL)
Default version status: unknown
0 to < *affected
Siemens FM Configuration Package
Default version status: unknown
0 to < *affected
Siemens Modular PID CTRL Tool
Default version status: unknown
0 to < *affected
Siemens MultiFieldbus Configuration Tool (MFCT)
Default version status: unknown
0 to < V1.5.5.0affected
Siemens OpenPCS 7 V10.0
Default version status: unknown
0 to < *affected
Siemens OpenPCS 7 V9.1
Default version status: unknown
0 to < *affected
Siemens Siemens Network Planner (SINETPLAN)
Default version status: unknown
0 to < V2.0 SP2affected
Siemens SIMATIC Automation Tool
Default version status: unknown
0 to < V5.0 SP4affected
Siemens SIMATIC Automation Tool SDK Windows
Default version status: unknown
0 to < V5.0 SP4affected
Siemens SIMATIC BATCH V10.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC BATCH V9.1
Default version status: unknown
0 to < *affected
Siemens SIMATIC Control Function Library (CFL) V1.x
Default version status: unknown
0 to < *affected
Siemens SIMATIC Control Function Library (CFL) V2.x
Default version status: unknown
0 to < *affected
Siemens SIMATIC Control Function Library (CFL) V3.x
Default version status: unknown
0 to < V3.1.0.2affected
Siemens SIMATIC Control Function Library (CFL) V4.x
Default version status: unknown
0 to < V4.1affected
Siemens SIMATIC D7-SYS
Default version status: unknown
0 to < V10.0 SP1affected
Siemens SIMATIC eaSie Core Package
Default version status: unknown
0 to < *affected
Siemens SIMATIC eaSie Document Skills
Default version status: unknown
0 to < *affected
Siemens SIMATIC eaSie PCS 7 Skill Package
Default version status: unknown
0 to < *affected
Siemens SIMATIC eaSie Workflow Skills
Default version status: unknown
0 to < *affected
Siemens SIMATIC Energy Suite V17
Default version status: unknown
0 to < *affected
Siemens SIMATIC Energy Suite V18
Default version status: unknown
0 to < *affected
Siemens SIMATIC Energy Suite V19
Default version status: unknown
0 to < V19 Update 4affected
Siemens SIMATIC Logon V1.6
Default version status: unknown
0 to < *affected
Siemens SIMATIC Logon V2.0
Default version status: unknown
0 to < V2.0 Upd3affected
Siemens SIMATIC Management Agent
Default version status: unknown
0 to < V9.1 SP1 Upd8affected
Siemens SIMATIC Management Console
Default version status: unknown
0 to < V9.1 SP1 Upd8affected
Siemens SIMATIC MTP CREATOR V2.x
Default version status: unknown
0 to < V2.1affected
Siemens SIMATIC MTP CREATOR V3.x
Default version status: unknown
0 to < *affected
Siemens SIMATIC MTP CREATOR V4.x
Default version status: unknown
0 to < V4.1.0.1affected
Siemens SIMATIC MTP CREATOR V5.x
Default version status: unknown
0 to < V5.0.0.1affected
Siemens SIMATIC MTP Integrator V1.x
Default version status: unknown
0 to < *affected
Siemens SIMATIC MTP Integrator V2.x
Default version status: unknown
0 to < *affected
Siemens SIMATIC NET PC Software V16
Default version status: unknown
0 to < *affected
Siemens SIMATIC NET PC Software V17
Default version status: unknown
0 to < *affected
Siemens SIMATIC NET PC Software V18
Default version status: unknown
0 to < *affected
Siemens SIMATIC NET PC Software V19
Default version status: unknown
0 to < *affected
Siemens SIMATIC NET PC Software V20
Default version status: unknown
0 to < V20.0 Update 1affected
Siemens SIMATIC ODK 1500S
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Advanced Process Faceplates V9.1
Default version status: unknown
0 to < V9.1 SP2 Upd4affected
Siemens SIMATIC PCS 7 Advanced Process Functions V2.1
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Advanced Process Functions V2.2
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Advanced Process Graphics V10.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Advanced Process Graphics V9.1
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Advanced Process Library V9.1
Default version status: unknown
0 to < V9.1 SP2 Upd6affected
Siemens SIMATIC PCS 7 Basis Faceplates V9.1
Default version status: unknown
0 to < V9.1 SP2 Upd2affected
Siemens SIMATIC PCS 7 Basis Library V10.0
Default version status: unknown
0 to < V10.0 SP1 Upd2affected
Siemens SIMATIC PCS 7 Basis Library V9.1
Default version status: unknown
0 to < V9.1 SP2 Upd8affected
Siemens SIMATIC PCS 7 Industry Library V10.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Industry Library V9.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Industry Library V9.1
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Logic Matrix V10.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Logic Matrix V9.1
Default version status: unknown
0 to < V9.1 Upd8affected
Siemens SIMATIC PCS 7 MPC Configurator
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 PowerControl V9.1
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Standard Chemical Library V10.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 Standard Chemical Library V9.1
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 TeleControl V9.1
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS 7 V10.0
Default version status: unknown
0 to < V10.0 SP1 UC01affected
Siemens SIMATIC PCS 7 V9.1
Default version status: unknown
0 to < V9.1 SP1 UC08affected
Siemens SIMATIC PCS 7/OPEN OS V9.1
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS neo V5.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC PCS neo V6.0
Default version status: unknown
0 to < V6.0 SP1affected
Siemens SIMATIC PDM Maintenance Station V5.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC PDM V9.2
Default version status: unknown
0 to < *affected
Siemens SIMATIC PDM V9.3
Default version status: unknown
0 to < V9.3 SP1 Upd2affected
Siemens SIMATIC Process Function Library (PFL) V4.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC Process Historian 2020
Default version status: unknown
0 to < *affected
Siemens SIMATIC Process Historian 2022
Default version status: unknown
0 to < *affected
Siemens SIMATIC Process Historian 2024
Default version status: unknown
0 to < V2024 SP1 Upd2affected
Siemens SIMATIC ProSave V17
Default version status: unknown
0 to < V17 Update 9affected
Siemens SIMATIC ProSave V18
Default version status: unknown
0 to < *affected
Siemens SIMATIC ProSave V19
Default version status: unknown
0 to < V19 Update 4affected
Siemens SIMATIC ProSave V20
Default version status: unknown
0 to < *affected
Siemens SIMATIC Route Control V10.0
Default version status: unknown
0 to < *affected
Siemens SIMATIC Route Control V9.1
Default version status: unknown
0 to < *affected
Siemens SIMATIC S7 F Systems V6.3
Default version status: unknown
0 to < *affected
Siemens SIMATIC S7 F Systems V6.4
Default version status: unknown
0 to < *affected
Siemens SIMATIC S7-1500 Software Controller V2
Default version status: unknown
0 to < *affected
Siemens SIMATIC S7-1500 Software Controller V3
Default version status: unknown
0 to < V31.1.5affected
Siemens SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)
Default version status: unknown
0 to < V4.0.1affected
Siemens SIMATIC S7-PCT
Default version status: unknown
0 to < V3.5 SP4 Update 1affected
Siemens SIMATIC S7-PLCSIM Advanced
Default version status: unknown
0 to < V7.0 Update 1affected
Siemens SIMATIC S7-PLCSIM V17
Default version status: unknown
0 to < *affected
Siemens SIMATIC S7-PLCSIM V18
Default version status: unknown
0 to < *affected
Siemens SIMATIC S7-PLCSIM V19
Default version status: unknown
0 to < *affected
Siemens SIMATIC S7-PLCSIM V20
Default version status: unknown
0 to < V20 Update 1affected
Siemens SIMATIC Safety Matrix V6.3
Default version status: unknown
0 to < *affected
Siemens SIMATIC STEP 7 CFC V19
Default version status: unknown
0 to < *affected
Siemens SIMATIC STEP 7 CFC V20
Default version status: unknown
0 to < *affected
Siemens SIMATIC STEP 7 V5.7
Default version status: unknown
0 to < *affected
Siemens SIMATIC Target
Default version status: unknown
0 to < V6.0 SP3affected
Siemens SIMATIC WinCC flexible ES
Default version status: unknown
0 to < *affected
Siemens SIMATIC WinCC Runtime Advanced
Default version status: unknown
0 to < V17 Update 9affected
Siemens SIMATIC WinCC Runtime Professional
Default version status: unknown
0 to < V21affected
Siemens SIMATIC WinCC Runtime Professional V20
Default version status: unknown
0 to < *affected
Siemens SIMATIC WinCC TeleControl
Default version status: unknown
0 to < *affected
Siemens SIMATIC WinCC Unified Line Coordination
Default version status: unknown
0 to < V20affected
Siemens SIMATIC WinCC Unified PC Runtime V18
Default version status: unknown
0 to < *affected
Siemens SIMATIC WinCC Unified PC Runtime V19
Default version status: unknown
0 to < *affected
Siemens SIMATIC WinCC Unified PC Runtime V20
Default version status: unknown
0 to < *affected
Siemens SIMATIC WinCC Unified Sequence
Default version status: unknown
0 to < V20affected
Siemens SIMATIC WinCC V7.5
Default version status: unknown
0 to < V7.5 SP2 Update 20affected
Siemens SIMATIC WinCC V8.0
Default version status: unknown
0 to < V8.0 Update 8affected
Siemens SIMATIC WinCC V8.1
Default version status: unknown
0 to < V8.1 Update 3affected
Siemens SIMATIC WinCC Visualization Architect (SiVArc) V17
Default version status: unknown
0 to < V17 Update 9affected
Siemens SIMATIC WinCC Visualization Architect (SiVArc) V18
Default version status: unknown
0 to < *affected
Siemens SIMATIC WinCC Visualization Architect (SiVArc) V19
Default version status: unknown
0 to < V19 Update 4affected
Siemens SIMATIC WinCC Visualization Architect (SiVArc) V20
Default version status: unknown
0 to < V20 Update 3affected
Siemens SIMIT Rapid Tester
Default version status: unknown
0 to < *affected
Siemens SIMIT Simulation Platform
Default version status: unknown
0 to < *affected
Siemens SINAMICS Startdrive V17
Default version status: unknown
0 to < *affected
Siemens SINAMICS Startdrive V18
Default version status: unknown
0 to < *affected
Siemens SINAMICS Startdrive V19
Default version status: unknown
0 to < *affected
Siemens SINAMICS Startdrive V20
Default version status: unknown
0 to < *affected
Siemens SINEC NMS
Default version status: unknown
0 to < V4.0affected
Siemens SINEMA Remote Connect Client
Default version status: unknown
0 to < *affected
Siemens SITRANS
Default version status: unknown
0 to < *affected
Siemens Standard PID CTRL Tool
Default version status: unknown
0 to < *affected
Siemens TeleControl Server Basic V3.1
Default version status: unknown
0 to < V3.1.2.2affected
Siemens TIA Administrator
Default version status: unknown
0 to < V3.0.6affected
Siemens TIA Portal Cloud Connector
Default version status: unknown
0 to < V2.3affected
Siemens TIA Portal Test Suite V17
Default version status: unknown
0 to < *affected
Siemens TIA Portal Test Suite V18
Default version status: unknown
0 to < *affected
Siemens TIA Portal Test Suite V19
Default version status: unknown
0 to < V19 Update 4affected
Siemens TIA Portal Test Suite V20
Default version status: unknown
0 to < V20 Update 3affected
Siemens TIA Project-Server
Default version status: unknown
0 to < V2.2affected
Siemens TIA Project-Server V17
Default version status: unknown
0 to < *affected
Siemens Totally Integrated Automation Portal (TIA Portal) V17
Default version status: unknown
0 to < V17 Update 9affected
Siemens Totally Integrated Automation Portal (TIA Portal) V18
Default version status: unknown
0 to < V18 Update 6affected
Siemens Totally Integrated Automation Portal (TIA Portal) V19
Default version status: unknown
0 to < V19 Update 4affected
Siemens Totally Integrated Automation Portal (TIA Portal) V20
Default version status: unknown
0 to < V20 Update 4affected
Siemens WinCC Panel Image Setup
Default version status: unknown
0 to < V17 Update 9affected