Description
For failed login attempts, the application returns different error messages depending on whether the login failed due to an incorrect password or a non-existing username. This allows an attacker to guess usernames until they find an existing one.
Affected products
Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.
Endress+Hauser Endress+Hauser MEAC300-FNADE4
Default version status: unaffected
0 to ≤ <=0.16.0affected
Endress+Hauser Endress+Hauser MEAC300-FNADE4
Default version status: affected
>=0.17.0unaffected
References
- https://www.endress.com ↗
- https://sick.com/psirt ↗
- https://www.cisa.gov/resources-tools/resources/ics-recommended-practices ↗
- https://www.first.org/cvss/calculator/3.1 ↗
- https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0008.json ↗
- https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0008.pdf ↗