Skip to content
CVE PROGRAM SOURCE RECORD8.6 High

CVE-2024-54678

A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7

Description

A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.

Affected products

Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.

Siemens SIMATIC PCS neo V4.1

Default version status: unknown

  • 0 to < *affected

Siemens SIMATIC PCS neo V5.0

Default version status: unknown

  • 0 to < *affected

Siemens SIMATIC PCS neo V6.0

Default version status: unknown

  • 0 to < V6.0 SP1 Update 1affected

Siemens SIMATIC S7-PLCSIM V17

Default version status: unknown

  • 0 to < *affected

Siemens SIMATIC STEP 7 V17

Default version status: unknown

  • 0 to < V17 Update 9affected

Siemens SIMATIC STEP 7 V18

Default version status: unknown

  • 0 to < V18 Update 6affected

Siemens SIMATIC STEP 7 V19

Default version status: unknown

  • 0 to < V19 Update 4affected

Siemens SIMATIC STEP 7 V20

Default version status: unknown

  • 0 to < V20 Update 4affected

Siemens SIMATIC WinCC V17

Default version status: unknown

  • 0 to < V17 Update 9affected

Siemens SIMATIC WinCC V18

Default version status: unknown

  • 0 to < V18 Update 6affected

Siemens SIMATIC WinCC V19

Default version status: unknown

  • 0 to < V19 Update 4affected

Siemens SIMATIC WinCC V20

Default version status: unknown

  • 0 to < V20 Update 4affected

Siemens SIMOCODE ES V17

Default version status: unknown

  • 0 to < *affected

Siemens SIMOCODE ES V18

Default version status: unknown

  • 0 to < *affected

Siemens SIMOCODE ES V19

Default version status: unknown

  • 0 to < *affected

Siemens SIMOCODE ES V20

Default version status: unknown

  • 0 to < *affected

Siemens SIMOTION SCOUT TIA V5.4

Default version status: unknown

  • 0 to < *affected

Siemens SIMOTION SCOUT TIA V5.5

Default version status: unknown

  • 0 to < *affected

Siemens SIMOTION SCOUT TIA V5.6

Default version status: unknown

  • 0 to < V5.6 SP1 HF7affected

Siemens SIMOTION SCOUT TIA V5.7

Default version status: unknown

  • 0 to < *affected

Siemens SINAMICS Startdrive V17

Default version status: unknown

  • 0 to < *affected

Siemens SINAMICS Startdrive V18

Default version status: unknown

  • 0 to < *affected

Siemens SINAMICS Startdrive V19

Default version status: unknown

  • 0 to < *affected

Siemens SINAMICS Startdrive V20

Default version status: unknown

  • 0 to < *affected

Siemens SIRIUS Safety ES V17 (TIA Portal)

Default version status: unknown

  • 0 to < *affected

Siemens SIRIUS Safety ES V18 (TIA Portal)

Default version status: unknown

  • 0 to < *affected

Siemens SIRIUS Safety ES V19 (TIA Portal)

Default version status: unknown

  • 0 to < *affected

Siemens SIRIUS Safety ES V20 (TIA Portal)

Default version status: unknown

  • 0 to < *affected

Siemens SIRIUS Soft Starter ES V17 (TIA Portal)

Default version status: unknown

  • 0 to < *affected

Siemens SIRIUS Soft Starter ES V18 (TIA Portal)

Default version status: unknown

  • 0 to < *affected

Siemens SIRIUS Soft Starter ES V19 (TIA Portal)

Default version status: unknown

  • 0 to < *affected

Siemens SIRIUS Soft Starter ES V20 (TIA Portal)

Default version status: unknown

  • 0 to < *affected

Siemens TIA Portal Cloud V17

Default version status: unknown

  • 0 to < *affected

Siemens TIA Portal Cloud V18

Default version status: unknown

  • 0 to < V6.3.0.2affected

Siemens TIA Portal Cloud V19

Default version status: unknown

  • 0 to < V5.2.1.1affected

Siemens TIA Portal Cloud V20

Default version status: unknown

  • 0 to < V5.2.2.2affected

Siemens TIA Portal Test Suite V20

Default version status: unknown

  • 0 to < V20 Update 4affected

References