Description
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
Affected products
Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.
Siemens SIMATIC STEP 7 Safety V16
Default version status: unknown
0 to < V16 Update 7affected
Siemens SIMATIC STEP 7 Safety V17
Default version status: unknown
0 to < V17 Update 7affected
Siemens SIMATIC STEP 7 Safety V18
Default version status: unknown
0 to < V18 Update 2affected
Siemens SIMATIC STEP 7 V16
Default version status: unknown
0 to < V16 Update 7affected
Siemens SIMATIC STEP 7 V17
Default version status: unknown
0 to < V17 Update 7affected
Siemens SIMATIC STEP 7 V18
Default version status: unknown
0 to < V18 Update 2affected
Siemens SIMATIC WinCC Unified V16
Default version status: unknown
0 to < V16 Update 7affected
Siemens SIMATIC WinCC Unified V17
Default version status: unknown
0 to < V17 Update 7affected
Siemens SIMATIC WinCC Unified V18
Default version status: unknown
0 to < V18 Update 2affected
Siemens SIMATIC WinCC V16
Default version status: unknown
0 to < V16.7affected
Siemens SIMATIC WinCC V17
Default version status: unknown
0 to < V17.7affected
Siemens SIMATIC WinCC V18
Default version status: unknown
0 to < V18 Update 2affected
Siemens SIMOCODE ES V16
Default version status: unknown
0 to < V16 Update 7affected
Siemens SIMOCODE ES V17
Default version status: unknown
0 to < V17 Update 7affected
Siemens SIMOCODE ES V18
Default version status: unknown
0 to < V18 Update 2affected
Siemens SIMOTION SCOUT TIA V5.4 SP1
Default version status: unknown
0 to < *affected
Siemens SIMOTION SCOUT TIA V5.4 SP3
Default version status: unknown
0 to < *affected
Siemens SIMOTION SCOUT TIA V5.5 SP1
Default version status: unknown
0 to < *affected
Siemens SINAMICS Startdrive V16
Default version status: unknown
0 to < *affected
Siemens SINAMICS Startdrive V17
Default version status: unknown
0 to < *affected
Siemens SINAMICS Startdrive V18
Default version status: unknown
0 to < *affected
Siemens SIRIUS Safety ES V17
Default version status: unknown
0 to < V17 Update 7affected
Siemens SIRIUS Safety ES V18
Default version status: unknown
0 to < V18 Update 2affected
Siemens SIRIUS Soft Starter ES V17
Default version status: unknown
0 to < V17 Update 7affected
Siemens SIRIUS Soft Starter ES V18
Default version status: unknown
0 to < V18 Update 2affected
Siemens Soft Starter ES V16
Default version status: unknown
0 to < V16 Update 7affected
Siemens TIA Portal Cloud V3.0
Default version status: unknown
0 to < V18 Update 2affected