Skip to content
CVE PROGRAM SOURCE RECORDUnscored

CVE-2022-39137

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid

Description

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17276)

Affected products

Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.

Siemens Parasolid V33.1

  • All versions < V33.1.262affected

Siemens Parasolid V34.0

  • All versions < V34.0.252affected

Siemens Parasolid V34.1

  • All versions < V34.1.242affected

Siemens Parasolid V35.0

  • All versions < V35.0.161affected

Siemens Simcenter Femap V2022.1

  • All versions < V2022.1.3affected

Siemens Simcenter Femap V2022.2

  • All versions < V2022.2.2affected

References