Skip to content
CVE PROGRAM SOURCE RECORD8.2 High

CVE-2022-35877

Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configu

Description

Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` configuration parameter, as used within the `testWifiAP` XCMD handler

Affected products

Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.

abode systems, inc. iota All-In-One Security Kit

  • 6.9Xaffected
  • 6.9Zaffected

References