Skip to content
CVE PROGRAM SOURCE RECORD5.9 Medium

CVE-2022-27221

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An attacker in machine-in-the-middle could obtain plaintext secret values by observing le

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An attacker in machine-in-the-middle could obtain plaintext secret values by observing length differences during a series of guesses in which a string in an HTTP request URL potentially matches an unknown string in an HTTP response body, aka a "BREACH" attack.

Affected products

Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.

Siemens SINEMA Remote Connect Server

Default version status: unknown

  • 0 to < V3.1affected

References