Description
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
Affected products
Version statuses are supplied by the assigning organization. Consult the original record for detailed ranges and platform conditions.
Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)
All versions < V15.1 Update 6affected
Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants)
All versions < V16 Update 4affected
Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants)
All versions < V15.1 Update 6affected
Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants)
All versions < V16 Update 4affected
Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F
All versions < V15.1 Update 6affected
Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F
All versions < V16 Update 4affected
Siemens SIMATIC WinCC Runtime Advanced V15
All versions < V15.1 Update 6affected
Siemens SIMATIC WinCC Runtime Advanced V16
All versions < V16 Update 4affected
Siemens SINAMICS GH150
All versionsaffected
Siemens SINAMICS GL150 (with option X30)
All versionsaffected
Siemens SINAMICS GM150 (with option X30)
All versionsaffected
Siemens SINAMICS SH150
All versionsaffected
Siemens SINAMICS SL150
All versionsaffected
Siemens SINAMICS SM120
All versionsaffected
Siemens SINAMICS SM150
All versionsaffected
Siemens SINAMICS SM150i
All versionsaffected