{"id":"CVE-2026-9716","state":"PUBLISHED","title":"CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when ma","description":"CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces.","publishedAt":"2026-06-25T15:02:28.169Z","updatedAt":"2026-06-25T15:49:59.528Z","severity":{"score":8.7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","source":"schneider"},"assigner":"schneider","products":["Schneider Electric PowerLogic™ P7"],"affected":[{"vendor":"Schneider Electric","product":"PowerLogic™ P7","defaultStatus":"unaffected","versions":[{"version":"Version V02.003.001.000 and prior","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-03.pdf"],"weaknesses":["CWE-476"],"ingestedAt":"2026-10-29T20:13:52.441Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/9xxx/CVE-2026-9716.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-9716","state":"PUBLISHED","datePublished":"2026-06-25T15:02:28.169Z","dateUpdated":"2026-06-25T15:49:59.528Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2026-05-27T16:02:10.007Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces."}],"affected":[{"vendor":"Schneider Electric","product":"PowerLogic™ P7","defaultStatus":"unaffected","versions":[{"version":"Version V02.003.001.000 and prior","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-03.pdf"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"HIGH","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-476","lang":"en","description":"CWE-476 NULL pointer dereference","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2026-06-25T15:02:28.169Z"},"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.2"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-06-25T15:49:53.446856Z","id":"CVE-2026-9716","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-06-25T15:49:59.528Z"}}]}}}