{"id":"CVE-2026-95748","state":"PUBLISHED","title":"Unauthenticated Adjacent SQL Injection Vulnerability in HPE Networking Fabric Composer","description":"A SQL injection vulnerability exists in HPE Networking Fabric Composer. Successful exploitation could allow an unauthenticated adjacent attacker to run arbitrary database commands.","publishedAt":"2026-11-03T19:51:05.332Z","updatedAt":"2026-11-09T12:42:17.686Z","severity":{"score":7.5,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"hpe"},"assigner":"hpe","products":["Hewlett Packard Enterprise (HPE) Fabric Composer"],"affected":[{"vendor":"Hewlett Packard Enterprise (HPE)","product":"Fabric Composer","defaultStatus":"affected","versions":[{"version":"7.4.0","status":"affected","lessThanOrEqual":"7.4.0","versionType":"semver"},{"version":"7.0.0","status":"affected","lessThanOrEqual":"7.3.4","versionType":"semver"}]}],"references":["https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05172en_us&docLocale=en_US"],"weaknesses":["CWE-89"],"ingestedAt":"2026-11-09T12:48:06.360Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/95xxx/CVE-2026-95748.json","commit":"2e14140c632c2cf844f2bd2109b285581cfd3f75","baselineCommit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-95748","state":"PUBLISHED","datePublished":"2026-11-03T19:51:05.332Z","dateUpdated":"2026-11-09T12:42:17.686Z","assignerShortName":"hpe","assignerOrgId":"eb103674-0d28-4225-80f8-39fb86215de0","dateReserved":"2026-09-22T14:53:35.472Z"},"containers":{"cna":{"title":"Unauthenticated Adjacent SQL Injection Vulnerability in HPE Networking Fabric Composer","descriptions":[{"lang":"en","value":"A SQL injection vulnerability exists in HPE Networking Fabric Composer. Successful exploitation could allow an unauthenticated adjacent attacker to run arbitrary database commands."}],"affected":[{"vendor":"Hewlett Packard Enterprise (HPE)","product":"Fabric Composer","defaultStatus":"affected","versions":[{"version":"7.4.0","status":"affected","lessThanOrEqual":"7.4.0","versionType":"semver"},{"version":"7.0.0","status":"affected","lessThanOrEqual":"7.3.4","versionType":"semver"}]}],"references":[{"url":"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05172en_us&docLocale=en_US"}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"ADJACENT_NETWORK","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","availabilityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"providerMetadata":{"shortName":"hpe","orgId":"eb103674-0d28-4225-80f8-39fb86215de0","dateUpdated":"2026-11-03T19:51:05.332Z"},"credits":[{"lang":"en","type":"reporter","value":"Internal security research (HPE Networking)."}],"source":{"advisory":"HPESBNW05172","discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-11-09T12:41:30.652437Z","id":"CVE-2026-95748","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-89","type":"CWE","lang":"en","description":"CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')"}]}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-11-09T12:42:17.686Z"}}]}}}