{"id":"CVE-2026-90720","state":"PUBLISHED","title":"Dell PowerProtect Data Domain, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40,","description":"Dell PowerProtect Data Domain, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Validation of Integrity Check Value vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Protection mechanism bypass.","publishedAt":"2026-10-28T08:32:31.338Z","updatedAt":"2026-10-30T03:56:11.819Z","severity":{"score":6.7,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","source":"dell"},"assigner":"dell","products":["Dell PowerProtect Data Domain"],"affected":[{"vendor":"Dell","product":"PowerProtect Data Domain","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"8.9.0.0 or later","versionType":"semver"},{"version":"0","status":"affected","lessThan":"7.13.1.90 or later","versionType":"semver"},{"version":"0","status":"affected","lessThan":"8.3.1.50 or later","versionType":"semver"},{"version":"0","status":"affected","lessThan":"8.6.1.30 or later","versionType":"semver"}]}],"references":["https://www.dell.com/support/kbdoc/en-us/000515178/dsa-2026-416-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"],"weaknesses":["CWE-354"],"ingestedAt":"2026-10-30T04:04:06.458Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/90xxx/CVE-2026-90720.json","commit":"3c00eb168943367a693dc912afa4276f983e7616","baselineCommit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-90720","state":"PUBLISHED","datePublished":"2026-10-28T08:32:31.338Z","dateUpdated":"2026-10-30T03:56:11.819Z","assignerShortName":"dell","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateReserved":"2026-09-13T10:04:17.591Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Dell PowerProtect Data Domain, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Validation of Integrity Check Value vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Protection mechanism bypass."}],"affected":[{"vendor":"Dell","product":"PowerProtect Data Domain","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"8.9.0.0 or later","versionType":"semver"},{"version":"0","status":"affected","lessThan":"7.13.1.90 or later","versionType":"semver"},{"version":"0","status":"affected","lessThan":"8.3.1.50 or later","versionType":"semver"},{"version":"0","status":"affected","lessThan":"8.6.1.30 or later","versionType":"semver"}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000515178/dsa-2026-416-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities","tags":["vendor-advisory"]}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV3_1":{"version":"3.1","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseSeverity":"MEDIUM","baseScore":6.7,"vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-354","lang":"en","description":"CWE-354: Improper Validation of Integrity Check Value","type":"CWE"}]}],"providerMetadata":{"shortName":"dell","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateUpdated":"2026-10-28T08:32:31.338Z"},"datePublic":"2026-10-01T06:30:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.5"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-10-29T00:00:00+00:00","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3","id":"CVE-2026-90720"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-10-30T03:56:11.819Z"}}]}}}