{"id":"CVE-2026-89198","state":"PUBLISHED","title":"A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize the filename of firmware files uploaded to th","description":"A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize the filename of firmware files uploaded to the system. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.","publishedAt":"2026-10-13T09:19:01.894Z","updatedAt":"2026-10-13T12:59:04.508Z","severity":{"score":8.7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens RUGGEDCOM CROSSBOW"],"affected":[{"vendor":"Siemens","product":"RUGGEDCOM CROSSBOW","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.0","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-508506.html"],"weaknesses":["CWE-89"],"ingestedAt":"2026-10-29T20:13:26.108Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/89xxx/CVE-2026-89198.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-89198","state":"PUBLISHED","datePublished":"2026-10-13T09:19:01.894Z","dateUpdated":"2026-10-13T12:59:04.508Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2026-09-11T07:45:20.918Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize the filename of firmware files uploaded to the system. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database."}],"affected":[{"vendor":"Siemens","product":"RUGGEDCOM CROSSBOW","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V6.0","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-508506.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":8.7,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-89","lang":"en","description":"CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2026-10-13T09:19:01.894Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-10-13T12:58:41.126504Z","id":"CVE-2026-89198","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-10-13T12:59:04.508Z"}}]}}}