{"id":"CVE-2026-85497","state":"PUBLISHED","title":"CareCam CM2507 Use of Password Hash With Insufficient Computational Effort","description":"CareCam CM2507 IP cameras store the device's root-account password using a fixed legacy password hash that provides insufficient resistance to offline cracking. An attacker who obtains the firmware image or password database could recover the associated credential, which may also be reusable across other devices running the same firmware.","publishedAt":"2026-09-18T16:19:23.396Z","updatedAt":"2026-09-21T18:46:26.392Z","severity":{"score":9.3,"label":"Critical","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"icscert"},"assigner":"icscert","products":["CareCam HMT.CM2507 Firmware"],"affected":[{"vendor":"CareCam","product":"HMT.CM2507 Firmware","defaultStatus":"affected","versions":[{"version":"v251211.1507","status":"affected"}]}],"references":["https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08","https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-08.json"],"weaknesses":["CWE-916"],"ingestedAt":"2026-10-29T20:13:15.269Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/85xxx/CVE-2026-85497.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-85497","state":"PUBLISHED","datePublished":"2026-09-18T16:19:23.396Z","dateUpdated":"2026-09-21T18:46:26.392Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2026-09-10T15:00:49.626Z"},"containers":{"cna":{"title":"CareCam CM2507 Use of Password Hash With Insufficient Computational Effort","descriptions":[{"lang":"en","value":"CareCam CM2507 IP cameras store the device's root-account password using a fixed legacy password hash that provides insufficient resistance to offline cracking. An attacker who obtains the firmware image or password database could recover the associated credential, which may also be reusable across other devices running the same firmware."}],"affected":[{"vendor":"CareCam","product":"HMT.CM2507 Firmware","defaultStatus":"affected","versions":[{"version":"v251211.1507","status":"affected"}]}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-08.json"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV3_1":{"version":"3.1","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseSeverity":"CRITICAL","baseScore":9.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"}},{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"CRITICAL","baseScore":9.3,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-916","lang":"en","description":"CWE-916","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateUpdated":"2026-09-18T16:19:23.396Z"},"workarounds":[{"lang":"en","value":"CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.","supportingMedia":[{"type":"text/html","base64":false,"value":"CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information."}]}],"credits":[{"lang":"en","value":"Ben Law reported this vulnerability to CISA.","type":"finder"}],"source":{"advisory":"ICSA-26-258-08","discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 1.0.5"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-09-21T18:46:18.091034Z","id":"CVE-2026-85497","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-09-21T18:46:26.392Z"}}]}}}