{"id":"CVE-2026-84400","state":"PUBLISHED","title":"CareCam CM2507 Missing Authentication for Critical Function","description":"CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access.","publishedAt":"2026-09-18T16:10:28.768Z","updatedAt":"2026-09-19T14:11:43.861Z","severity":{"score":2.3,"label":"Low","version":"4.0","vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N","source":"icscert"},"assigner":"icscert","products":["CareCam HMT.CM2507 Firmware"],"affected":[{"vendor":"CareCam","product":"HMT.CM2507 Firmware","defaultStatus":"affected","versions":[{"version":"v251211.1507","status":"affected"}]}],"references":["https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08","https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-08.json"],"weaknesses":["CWE-306"],"ingestedAt":"2026-10-29T20:13:15.269Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/84xxx/CVE-2026-84400.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-84400","state":"PUBLISHED","datePublished":"2026-09-18T16:10:28.768Z","dateUpdated":"2026-09-19T14:11:43.861Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2026-09-10T15:00:49.635Z"},"containers":{"cna":{"title":"CareCam CM2507 Missing Authentication for Critical Function","descriptions":[{"lang":"en","value":"CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access."}],"affected":[{"vendor":"CareCam","product":"HMT.CM2507 Firmware","defaultStatus":"affected","versions":[{"version":"v251211.1507","status":"affected"}]}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-08.json"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV3_1":{"version":"3.1","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE","baseSeverity":"LOW","baseScore":3.1,"vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N"}},{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"LOW","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"LOW","baseScore":2.3,"vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","lang":"en","description":"CWE-306","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateUpdated":"2026-09-18T16:10:28.768Z"},"workarounds":[{"lang":"en","value":"CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.","supportingMedia":[{"type":"text/html","base64":false,"value":"CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information."}]}],"credits":[{"lang":"en","value":"Ben Law reported this vulnerability to CISA.","type":"finder"}],"source":{"advisory":"ICSA-26-258-08","discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 1.0.5"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2026-84400","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2026-09-19T13:44:30.475992Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-09-19T14:11:43.861Z"}}]}}}