{"id":"CVE-2026-82791","state":"PUBLISHED","title":"Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this ","description":"Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.","publishedAt":"2026-09-14T06:45:22.083Z","updatedAt":"2026-09-14T12:07:55.617Z","severity":{"score":8.7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"jpcert"},"assigner":"jpcert","products":["Contec Co., Ltd. CAN-2-WF","Contec Co., Ltd. CAN-2-USB"],"affected":[{"vendor":"Contec Co., Ltd.","product":"CAN-2-WF","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"2.20","versionType":"semver"}]},{"vendor":"Contec Co., Ltd.","product":"CAN-2-USB","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"2.20","versionType":"semver"}]}],"references":["https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf","https://jvn.jp/en/vu/JVNVU90314828/"],"weaknesses":["CWE-78"],"ingestedAt":"2026-10-29T20:13:15.269Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/82xxx/CVE-2026-82791.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-82791","state":"PUBLISHED","datePublished":"2026-09-14T06:45:22.083Z","dateUpdated":"2026-09-14T12:07:55.617Z","assignerShortName":"jpcert","assignerOrgId":"ede6fdc4-6654-4307-a26d-3331c018e2ce","dateReserved":"2026-08-31T02:30:58.279Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product."}],"affected":[{"vendor":"Contec Co., Ltd.","product":"CAN-2-WF","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"2.20","versionType":"semver"}]},{"vendor":"Contec Co., Ltd.","product":"CAN-2-USB","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"2.20","versionType":"semver"}]}],"references":[{"url":"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"},{"url":"https://jvn.jp/en/vu/JVNVU90314828/"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en-US","value":"GENERAL"}],"cvssV3_1":{"version":"3.1","baseSeverity":"HIGH","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"}},{"format":"CVSS","scenarios":[{"lang":"en-US","value":"GENERAL"}],"cvssV4_0":{"version":"4.0","baseSeverity":"HIGH","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"Improper neutralization of special elements used in an OS command ('OS Command Injection')","lang":"en-US","type":"CWE"}]}],"providerMetadata":{"shortName":"jpcert","orgId":"ede6fdc4-6654-4307-a26d-3331c018e2ce","dateUpdated":"2026-09-14T06:45:22.083Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-09-14T12:07:44.065201Z","id":"CVE-2026-82791","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-09-14T12:07:55.617Z"}}]}}}