{"id":"CVE-2026-78574","state":"PUBLISHED","title":"Improper Assembly Resolution in Okta Hyperdrive Integration Plugin Registry Handling","description":"The Okta Hyperdrive Integration plugin resolves a required assembly using a registry path within the current user's hive without integrity verification. The referenced path is loaded via Assembly.LoadFrom without signature validation, resulting in an unverified assembly executing within the context of the host process or elevated installer.","publishedAt":"2026-09-08T20:11:43.869Z","updatedAt":"2026-09-10T14:36:50.101Z","severity":{"score":7.5,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N","source":"Okta"},"assigner":"Okta","products":["Okta Okta Hyperdrive Integration Plugin"],"affected":[{"vendor":"Okta","product":"Okta Hyperdrive Integration Plugin","defaultStatus":"unaffected","versions":[{"version":"1.2.0","status":"affected","lessThan":"1.5.2","versionType":"semver"}]}],"references":["https://trust.okta.com/security-advisories/improper-assembly-resolution-in-okta-hyperdrive-integration-plugin-registry-handling-cve-2026-78574"],"weaknesses":["CWE-426"],"ingestedAt":"2026-10-29T20:13:07.220Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/78xxx/CVE-2026-78574.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-78574","state":"PUBLISHED","datePublished":"2026-09-08T20:11:43.869Z","dateUpdated":"2026-09-10T14:36:50.101Z","assignerShortName":"Okta","assignerOrgId":"59b22baa-87b2-4371-8e4a-e080df12f74a","dateReserved":"2026-08-24T20:39:00.874Z"},"containers":{"cna":{"title":"Improper Assembly Resolution in Okta Hyperdrive Integration Plugin Registry Handling","descriptions":[{"lang":"en","value":"The Okta Hyperdrive Integration plugin resolves a required assembly using a registry path within the current user's hive without integrity verification. The referenced path is loaded via Assembly.LoadFrom without signature validation, resulting in an unverified assembly executing within the context of the host process or elevated installer."}],"affected":[{"vendor":"Okta","product":"Okta Hyperdrive Integration Plugin","defaultStatus":"unaffected","versions":[{"version":"1.2.0","status":"affected","lessThan":"1.5.2","versionType":"semver"}]}],"references":[{"url":"https://trust.okta.com/security-advisories/improper-assembly-resolution-in-okta-hyperdrive-integration-plugin-registry-handling-cve-2026-78574"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-426","lang":"en","description":"Untrusted Search Path"}]}],"providerMetadata":{"shortName":"Okta","orgId":"59b22baa-87b2-4371-8e4a-e080df12f74a","dateUpdated":"2026-09-08T20:11:43.869Z"},"solutions":[{"lang":"en","value":"Upgrade the Okta Hyperdrive Integration plugin to version 1.5.2 or greater."}]},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-09-10T14:36:30.614100Z","id":"CVE-2026-78574","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-09-10T14:36:50.101Z"}}]}}}