{"id":"CVE-2026-64629","state":"PUBLISHED","title":"A vulnerability has been identified in Parasolid V38.0 (All versions < V38.0.235), Parasolid V38.1 (All versions < V38.1.230). The affected applications contains an out of bounds r","description":"A vulnerability has been identified in Parasolid V38.0 (All versions < V38.0.235), Parasolid V38.1 (All versions < V38.1.230). The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.","publishedAt":"2026-08-11T12:20:29.453Z","updatedAt":"2026-08-12T19:19:40.181Z","severity":{"score":7.3,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens Parasolid V38.0","Siemens Parasolid V38.1"],"affected":[{"vendor":"Siemens","product":"Parasolid V38.0","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V38.0.235","versionType":"custom"}]},{"vendor":"Siemens","product":"Parasolid V38.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V38.1.230","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-138516.html"],"weaknesses":["CWE-125"],"ingestedAt":"2026-10-29T20:12:41.951Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/64xxx/CVE-2026-64629.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-64629","state":"PUBLISHED","datePublished":"2026-08-11T12:20:29.453Z","dateUpdated":"2026-08-12T19:19:40.181Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2026-07-20T13:21:17.902Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Parasolid V38.0 (All versions < V38.0.235), Parasolid V38.1 (All versions < V38.1.230). The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."}],"affected":[{"vendor":"Siemens","product":"Parasolid V38.0","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V38.0.235","versionType":"custom"}]},{"vendor":"Siemens","product":"Parasolid V38.1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V38.1.230","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-138516.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":7.3,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-125","lang":"en","description":"CWE-125: Out-of-bounds Read","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2026-08-11T12:20:29.453Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-08-12T17:58:57.173944Z","id":"CVE-2026-64629","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-08-12T19:19:40.181Z"}}]}}}