{"id":"CVE-2026-6332","state":"PUBLISHED","title":"Clear Text Storage of Sensitive Information on EcoStruxure™ Machine Expert HVAC","description":"CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that could cause the disclosure of a sensitive information  which could result in revealing protected source code and loss of confidentiality, When an authorized attacker accesses the source code for editing or compiling it.","publishedAt":"2026-05-14T16:54:50.465Z","updatedAt":"2026-05-14T18:37:23.728Z","severity":{"score":6.8,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","source":"schneider"},"assigner":"schneider","products":["Schneider Electric Ecostruxure™ Machine Expert HVAC"],"affected":[{"vendor":"Schneider Electric","product":"Ecostruxure™ Machine Expert HVAC","defaultStatus":"unaffected","versions":[{"version":"Versions prior to 1.10.0","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-01.pdf"],"weaknesses":["CWE-312"],"ingestedAt":"2026-10-29T20:12:49.727Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/6xxx/CVE-2026-6332.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-6332","state":"PUBLISHED","datePublished":"2026-05-14T16:54:50.465Z","dateUpdated":"2026-05-14T18:37:23.728Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2026-04-15T07:55:30.087Z"},"containers":{"cna":{"title":"Clear Text Storage of Sensitive Information on EcoStruxure™ Machine Expert HVAC","descriptions":[{"lang":"en","value":"CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that could cause the disclosure of a sensitive information  which could result in revealing protected source code and loss of confidentiality, When an authorized attacker accesses the source code for editing or compiling it."}],"affected":[{"vendor":"Schneider Electric","product":"Ecostruxure™ Machine Expert HVAC","defaultStatus":"unaffected","versions":[{"version":"Versions prior to 1.10.0","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-01.pdf"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"MEDIUM","baseScore":6.8,"vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-312","lang":"en","description":"CWE-312 Cleartext storage of sensitive information","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2026-05-14T16:54:50.465Z"},"datePublic":"2026-05-12T16:49:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.2"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-05-14T18:37:08.735767Z","id":"CVE-2026-6332","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-05-14T18:37:23.728Z"}}]}}}