{"id":"CVE-2026-62654","state":"PUBLISHED","title":"A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A special maintenance mode can be activated via a physical key sequence during device boot, in which th","description":"A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code.","publishedAt":"2026-09-08T08:11:35.239Z","updatedAt":"2026-09-08T12:24:28.328Z","severity":{"score":7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens Reyrolle 7SR5"],"affected":[{"vendor":"Siemens","product":"Reyrolle 7SR5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.70","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-142885.html"],"weaknesses":["CWE-494"],"ingestedAt":"2026-10-29T20:12:32.778Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/62xxx/CVE-2026-62654.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-62654","state":"PUBLISHED","datePublished":"2026-09-08T08:11:35.239Z","dateUpdated":"2026-09-08T12:24:28.328Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2026-07-14T16:24:23.430Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code."}],"affected":[{"vendor":"Siemens","product":"Reyrolle 7SR5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2.70","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-142885.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":6.8,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":7,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-494","lang":"en","description":"CWE-494: Download of Code Without Integrity Check","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2026-09-08T08:11:35.239Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-09-08T12:24:21.127677Z","id":"CVE-2026-62654","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-09-08T12:24:28.328Z"}}]}}}