{"id":"CVE-2026-4827","state":"PUBLISHED","title":"Insufficient Entropy vulnerability on Multiple Products","description":"CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.","publishedAt":"2026-05-12T12:24:22.928Z","updatedAt":"2026-05-14T17:38:38.647Z","severity":{"score":8.7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","source":"schneider"},"assigner":"schneider","products":["Schneider Electric Easergy MiCOM C264","Schneider Electric Easergy C5","Schneider Electric Easergy MiCOM P30","Schneider Electric Easergy MiCOM P40","Schneider Electric EcoStruxure™ Power Automation System Gateway (EPAS-GTW)","Schneider Electric EcoStruxure™ Power Automation System User Interface (EPAS-UI)","Schneider Electric EcoStruxure™ Power Operation","Schneider Electric iPMFLS","Schneider Electric PowerLogic™ P5 Protection Relay","Schneider Electric PowerLogic™ P7 Protection and Control Platform","Schneider Electric PowerLogic™ T300","Schneider Electric PowerLogic™ T500","Schneider Electric Saitel DP","Schneider Electric EasyLogic T150 (formerly Saitel DR)"],"affected":[{"vendor":"Schneider Electric","product":"Easergy MiCOM C264","defaultStatus":"unaffected","versions":[{"version":"Versions D6.x","status":"affected"},{"version":"Versions D7.33 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"Easergy C5","defaultStatus":"unaffected","versions":[{"version":"Version 1.1.17 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"Easergy MiCOM P30","defaultStatus":"unaffected","versions":[{"version":"P139 version prior to P139.678.700","status":"affected"},{"version":"P437 version prior to P437.678.700","status":"affected"},{"version":"P439 version prior to P439.678.700","status":"affected"},{"version":"P532 version prior to P532.678.700","status":"affected"},{"version":"P539 version prior to P539.678.700","status":"affected"},{"version":"P631 version prior to P631.678.700","status":"affected"},{"version":"P632 version prior to P632.678.700","status":"affected"},{"version":"P633 version prior to P633.678.700","status":"affected"},{"version":"P634 version prior to P634.678.700","status":"affected"},{"version":"P633 version P633.680.700 only","status":"affected"},{"version":"P634 version P634.680.700 only","status":"affected"},{"version":"P138 version prior to P138.677.700","status":"affected"},{"version":"P436 version prior to P436.677.701","status":"affected"},{"version":"P438 version prior to P438.677.701","status":"affected"},{"version":"P638 version prior to P638.677.700","status":"affected"},{"version":"C434 version prior to C434.679.700","status":"affected"}]},{"vendor":"Schneider Electric","product":"Easergy MiCOM P40","defaultStatus":"unaffected","versions":[{"version":"Series model numbers with Protocol Option bit as G, H or L and all firmware versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Automation System Gateway (EPAS-GTW)","defaultStatus":"unaffected","versions":[{"version":"Version 6.4.616.200.100 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Automation System User Interface (EPAS-UI)","defaultStatus":"unaffected","versions":[{"version":"Version 3.0.3 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Operation","defaultStatus":"unaffected","versions":[{"version":"Version 2022 CU6 and prior","status":"affected"},{"version":"Version 2024 CU2 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"iPMFLS","defaultStatus":"unaffected","versions":[{"version":"Version 64.2025.0.13 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ P5 Protection Relay","defaultStatus":"unaffected","versions":[{"version":"V02.502.103 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ P7 Protection and Control Platform","defaultStatus":"unaffected","versions":[{"version":"V02.002.002 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ T300","defaultStatus":"unaffected","versions":[{"version":"Version 2.9.4 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ T500","defaultStatus":"unaffected","versions":[{"version":"Version 11.08.02 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"Saitel DP","defaultStatus":"unaffected","versions":[{"version":"Version 11.06.36 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"EasyLogic T150 (formerly Saitel DR)","defaultStatus":"unaffected","versions":[{"version":"Version 11.06.30 and prior","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-02.pdf"],"weaknesses":["CWE-331"],"ingestedAt":"2026-10-29T20:12:16.098Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/4xxx/CVE-2026-4827.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-4827","state":"PUBLISHED","datePublished":"2026-05-12T12:24:22.928Z","dateUpdated":"2026-05-14T17:38:38.647Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2026-03-25T14:07:29.111Z"},"containers":{"cna":{"title":"Insufficient Entropy vulnerability on Multiple Products","descriptions":[{"lang":"en","value":"CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections."}],"affected":[{"vendor":"Schneider Electric","product":"Easergy MiCOM C264","defaultStatus":"unaffected","versions":[{"version":"Versions D6.x","status":"affected"},{"version":"Versions D7.33 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"Easergy C5","defaultStatus":"unaffected","versions":[{"version":"Version 1.1.17 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"Easergy MiCOM P30","defaultStatus":"unaffected","versions":[{"version":"P139 version prior to P139.678.700","status":"affected"},{"version":"P437 version prior to P437.678.700","status":"affected"},{"version":"P439 version prior to P439.678.700","status":"affected"},{"version":"P532 version prior to P532.678.700","status":"affected"},{"version":"P539 version prior to P539.678.700","status":"affected"},{"version":"P631 version prior to P631.678.700","status":"affected"},{"version":"P632 version prior to P632.678.700","status":"affected"},{"version":"P633 version prior to P633.678.700","status":"affected"},{"version":"P634 version prior to P634.678.700","status":"affected"},{"version":"P633 version P633.680.700 only","status":"affected"},{"version":"P634 version P634.680.700 only","status":"affected"},{"version":"P138 version prior to P138.677.700","status":"affected"},{"version":"P436 version prior to P436.677.701","status":"affected"},{"version":"P438 version prior to P438.677.701","status":"affected"},{"version":"P638 version prior to P638.677.700","status":"affected"},{"version":"C434 version prior to C434.679.700","status":"affected"}]},{"vendor":"Schneider Electric","product":"Easergy MiCOM P40","defaultStatus":"unaffected","versions":[{"version":"Series model numbers with Protocol Option bit as G, H or L and all firmware versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Automation System Gateway (EPAS-GTW)","defaultStatus":"unaffected","versions":[{"version":"Version 6.4.616.200.100 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Automation System User Interface (EPAS-UI)","defaultStatus":"unaffected","versions":[{"version":"Version 3.0.3 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"EcoStruxure™ Power Operation","defaultStatus":"unaffected","versions":[{"version":"Version 2022 CU6 and prior","status":"affected"},{"version":"Version 2024 CU2 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"iPMFLS","defaultStatus":"unaffected","versions":[{"version":"Version 64.2025.0.13 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ P5 Protection Relay","defaultStatus":"unaffected","versions":[{"version":"V02.502.103 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ P7 Protection and Control Platform","defaultStatus":"unaffected","versions":[{"version":"V02.002.002 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ T300","defaultStatus":"unaffected","versions":[{"version":"Version 2.9.4 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"PowerLogic™ T500","defaultStatus":"unaffected","versions":[{"version":"Version 11.08.02 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"Saitel DP","defaultStatus":"unaffected","versions":[{"version":"Version 11.06.36 and prior","status":"affected"}]},{"vendor":"Schneider Electric","product":"EasyLogic T150 (formerly Saitel DR)","defaultStatus":"unaffected","versions":[{"version":"Version 11.06.30 and prior","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-02.pdf"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"PASSIVE","vulnConfidentialityImpact":"HIGH","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"LOW","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"HIGH","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-331","lang":"en","description":"CWE-331 Insufficient entropy","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2026-05-14T17:38:38.647Z"},"datePublic":"2026-05-12T16:49:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.2"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-05-12T12:39:02.210471Z","id":"CVE-2026-4827","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-05-12T12:39:31.579Z"}}]}}}