{"id":"CVE-2026-4017","state":"PUBLISHED","title":"Buffer overflow in the QNX Neutrino kernel impacts versions of the QNX Software Development Platform and QNX OS for Safety","description":"Buffer Overflow in the entry handler of the TraceEvent() system call could allow an attacker with local access to cause information disclosure, data tampering or a crash of the QNX Neutrino kernel.","publishedAt":"2026-07-14T17:25:13.128Z","updatedAt":"2026-07-14T23:36:28.181Z","severity":{"score":7.4,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"blackberry"},"assigner":"blackberry","products":["BlackBerry Ltd QNX Software Development Platform","BlackBerry Ltd QNX OS for Safety","BlackBerry Ltd. QNX OS for Medical"],"affected":[{"vendor":"BlackBerry Ltd","product":"QNX Software Development Platform","defaultStatus":"unaffected","versions":[{"version":"7.1","status":"affected"},{"version":"cpe:2.3:a:blackberry:qnx_software_development_platform:7.1:*:*:*:*:*:*:*","status":"affected","versionType":"cpe"},{"version":"7.0","status":"affected"},{"version":"cpe:2.3:a:blackberry:qnx_software_development_platform:7.0:*:*:*:*:*:*:*","status":"affected","versionType":"cpe"}]},{"vendor":"BlackBerry Ltd","product":"QNX OS for Safety","defaultStatus":"unaffected","versions":[{"version":"2.2.8 and earlier","status":"affected"},{"version":"cpe:2.3:o:blackberry:qnx_os_for_safety:2.2:8:*:*:*:*:*:*","status":"affected","versionType":"cpe"},{"version":"2.1.5 and earlier","status":"affected"},{"version":"cpe:2.3:o:blackberry:qnx_os_for_safety:2.1:5:*:*:*:*:*:*","status":"affected","versionType":"cpe"},{"version":"2.0.3 and earlier","status":"affected"},{"version":"cpe:2.3:o:blackberry:qnx_os_for_safety:2.0:3:*:*:*:*:*:*","status":"affected","versionType":"cpe"}]},{"vendor":"BlackBerry Ltd.","product":"QNX OS for Medical","defaultStatus":"unaffected","versions":[{"version":"2.0.2 and earlier","status":"affected"},{"version":"cpe:2.3:o:blackberry:qnx_os_for_medical:2.0:2:*:*:*:*:*:*","status":"affected","versionType":"cpe"}]}],"references":["https://support.blackberry.com/pkb/s/article/141213"],"weaknesses":["CWE-121"],"ingestedAt":"2026-10-29T20:12:16.098Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/4xxx/CVE-2026-4017.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-4017","state":"PUBLISHED","datePublished":"2026-07-14T17:25:13.128Z","dateUpdated":"2026-07-14T23:36:28.181Z","assignerShortName":"blackberry","assignerOrgId":"dbe78b00-5e7b-4fda-8748-329789ecfc5c","dateReserved":"2026-03-11T19:20:13.205Z"},"containers":{"cna":{"title":"Buffer overflow in the QNX Neutrino kernel impacts versions of the QNX Software Development Platform and QNX OS for Safety","descriptions":[{"lang":"en","value":"Buffer Overflow in the entry handler of the TraceEvent() system call could allow an attacker with local access to cause information disclosure, data tampering or a crash of the QNX Neutrino kernel."}],"affected":[{"vendor":"BlackBerry Ltd","product":"QNX Software Development Platform","defaultStatus":"unaffected","versions":[{"version":"7.1","status":"affected"},{"version":"cpe:2.3:a:blackberry:qnx_software_development_platform:7.1:*:*:*:*:*:*:*","status":"affected","versionType":"cpe"},{"version":"7.0","status":"affected"},{"version":"cpe:2.3:a:blackberry:qnx_software_development_platform:7.0:*:*:*:*:*:*:*","status":"affected","versionType":"cpe"}]},{"vendor":"BlackBerry Ltd","product":"QNX OS for Safety","defaultStatus":"unaffected","versions":[{"version":"2.2.8 and earlier","status":"affected"},{"version":"cpe:2.3:o:blackberry:qnx_os_for_safety:2.2:8:*:*:*:*:*:*","status":"affected","versionType":"cpe"},{"version":"2.1.5 and earlier","status":"affected"},{"version":"cpe:2.3:o:blackberry:qnx_os_for_safety:2.1:5:*:*:*:*:*:*","status":"affected","versionType":"cpe"},{"version":"2.0.3 and earlier","status":"affected"},{"version":"cpe:2.3:o:blackberry:qnx_os_for_safety:2.0:3:*:*:*:*:*:*","status":"affected","versionType":"cpe"}]},{"vendor":"BlackBerry Ltd.","product":"QNX OS for Medical","defaultStatus":"unaffected","versions":[{"version":"2.0.2 and earlier","status":"affected"},{"version":"cpe:2.3:o:blackberry:qnx_os_for_medical:2.0:2:*:*:*:*:*:*","status":"affected","versionType":"cpe"}]}],"references":[{"url":"https://support.blackberry.com/pkb/s/article/141213"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV3_1":{"version":"3.1","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseSeverity":"HIGH","baseScore":7.4,"vectorString":"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","lang":"en","description":"CWE-121 Stack-based buffer overflow","type":"CWE"}]}],"providerMetadata":{"shortName":"blackberry","orgId":"dbe78b00-5e7b-4fda-8748-329789ecfc5c","dateUpdated":"2026-07-14T17:25:13.128Z"},"datePublic":"2026-07-14T15:15:00.000Z","impacts":[{"capecId":"CAPEC-100","descriptions":[{"lang":"en","value":"CAPEC-100 Overflow Buffers"}]}],"source":{"advisory":"https://support.blackberry.com/pkb/s/article/141213","discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.2"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-07-14T23:36:16.979515Z","id":"CVE-2026-4017","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-07-14T23:36:28.181Z"}}]}}}