{"id":"CVE-2026-2404","state":"PUBLISHED","title":"CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payloa","description":"CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload.","publishedAt":"2026-04-14T15:13:50.351Z","updatedAt":"2026-04-14T16:27:43.927Z","severity":{"score":6.9,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N","source":"schneider"},"assigner":"schneider","products":["Schneider Electric PowerChute™ Serial Shutdown"],"affected":[{"vendor":"Schneider Electric","product":"PowerChute™ Serial Shutdown","defaultStatus":"unaffected","versions":[{"version":"Versions 1.4 and prior","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf"],"weaknesses":["CWE-116"],"ingestedAt":"2026-10-29T20:11:31.369Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/2xxx/CVE-2026-2404.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-2404","state":"PUBLISHED","datePublished":"2026-04-14T15:13:50.351Z","dateUpdated":"2026-04-14T16:27:43.927Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2026-02-12T13:19:03.924Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload."}],"affected":[{"vendor":"Schneider Electric","product":"PowerChute™ Serial Shutdown","defaultStatus":"unaffected","versions":[{"version":"Versions 1.4 and prior","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"LOW","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"MEDIUM","baseScore":6.9,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-116","lang":"en","description":"CWE-116 Improper Encoding or Escaping of Output","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2026-04-14T15:13:50.351Z"},"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.1"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-04-14T16:26:32.467506Z","id":"CVE-2026-2404","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-04-14T16:27:43.927Z"}}]}}}