{"id":"CVE-2026-22918","state":"PUBLISHED","title":"An attacker may exploit missing protection against clickjacking by tricking users into performing unintended actions through maliciously crafted web pages, leading to the extractio","description":"An attacker may exploit missing protection against clickjacking by tricking users into performing unintended actions through maliciously crafted web pages, leading to the extraction of sensitive data.","publishedAt":"2026-01-15T13:08:02.039Z","updatedAt":"2026-01-15T14:36:41.215Z","severity":{"score":4.3,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","source":"SICK AG"},"assigner":"SICK AG","products":["SICK AG TDC-X401GL"],"affected":[{"vendor":"SICK AG","product":"TDC-X401GL","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected","versionType":"custom"}]}],"references":["https://sick.com/psirt","https://www.sick.com/media/docs/9/19/719/special_information_sick_operating_guidelines_cybersecurity_by_sick_en_im0106719.pdf","https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","https://www.first.org/cvss/calculator/3.1","https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0001.json","https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0001.pdf"],"weaknesses":["CWE-1021"],"ingestedAt":"2026-10-29T20:11:21.040Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/22xxx/CVE-2026-22918.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-22918","state":"PUBLISHED","datePublished":"2026-01-15T13:08:02.039Z","dateUpdated":"2026-01-15T14:36:41.215Z","assignerShortName":"SICK AG","assignerOrgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateReserved":"2026-01-13T09:11:12.759Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"An attacker may exploit missing protection against clickjacking by tricking users into performing unintended actions through maliciously crafted web pages, leading to the extraction of sensitive data."}],"affected":[{"vendor":"SICK AG","product":"TDC-X401GL","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected","versionType":"custom"}]}],"references":[{"url":"https://sick.com/psirt","tags":["x_SICK PSIRT Security Advisories"]},{"url":"https://www.sick.com/media/docs/9/19/719/special_information_sick_operating_guidelines_cybersecurity_by_sick_en_im0106719.pdf","tags":["x_SICK Operating Guidelines"]},{"url":"https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","tags":["x_ICS-CERT recommended practices on Industrial Security"]},{"url":"https://www.first.org/cvss/calculator/3.1","tags":["x_CVSS v3.1 Calculator"]},{"url":"https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0001.json","tags":["x_The canonical URL."]},{"url":"https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0001.pdf","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","environmentalScore":4.3,"environmentalSeverity":"MEDIUM","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","temporalScore":4.3,"temporalSeverity":"MEDIUM","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1021","description":"CWE-1021 Improper Restriction of Rendered UI Layers or Frames","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"SICK AG","orgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateUpdated":"2026-01-15T13:08:02.039Z"},"source":{"advisory":"SCA-2026-0001","discovery":"INTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \"SICK Operating Guidelines\" and \"ICS-CERT recommended practices on Industrial Security\" could help to implement the general security practices.</p>"}],"value":"Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \"SICK Operating Guidelines\" and \"ICS-CERT recommended practices on Industrial Security\" could help to implement the general security practices."}],"x_generator":{"engine":"csaf2cve 0.2.1"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-01-15T14:35:41.085453Z","id":"CVE-2026-22918","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-01-15T14:36:41.215Z"}}]}}}