{"id":"CVE-2026-12655","state":"PUBLISHED","title":"1732E ArmorBlock® - Multiple Vulnerabilities","description":"A security issue exists within 1732E ArmorBlock® I/O, where an unauthenticated attacker can change the device's webserver password without valid credentials. This could result in admin account takeover or unauthorized modification of device configuration.","publishedAt":"2026-10-13T14:08:36.952Z","updatedAt":"2026-10-15T19:14:57.983Z","severity":{"score":8.8,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N","source":"Rockwell"},"assigner":"Rockwell","products":["Rockwell Automation 1732E ArmorBlock® I/O"],"affected":[{"vendor":"Rockwell Automation","product":"1732E ArmorBlock® I/O","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"3.012","versionType":"custom"}]}],"references":["https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1801.html"],"weaknesses":["CWE-294"],"ingestedAt":"2026-10-29T20:10:52.580Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/12xxx/CVE-2026-12655.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-12655","state":"PUBLISHED","datePublished":"2026-10-13T14:08:36.952Z","dateUpdated":"2026-10-15T19:14:57.983Z","assignerShortName":"Rockwell","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","dateReserved":"2026-06-18T18:48:53.410Z"},"containers":{"cna":{"title":"1732E ArmorBlock® - Multiple Vulnerabilities","descriptions":[{"lang":"en","value":"A security issue exists within 1732E ArmorBlock® I/O, where an unauthenticated attacker can change the device's webserver password without valid credentials. This could result in admin account takeover or unauthorized modification of device configuration."}],"affected":[{"vendor":"Rockwell Automation","product":"1732E ArmorBlock® I/O","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThanOrEqual":"3.012","versionType":"custom"}]}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1801.html"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-294","description":"CWE-294: Authentication Bypass by Capture-replay","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Rockwell","orgId":"b73dd486-f505-4403-b634-40b078b177f0","dateUpdated":"2026-10-13T14:08:36.952Z"},"datePublic":"2026-10-13T13:00:00.000Z","solutions":[{"lang":"en","value":"3.013 or later","supportingMedia":[{"base64":false,"type":"text/html","value":"3.013 or later"}]}],"source":{"advisory":"SD1801","discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2026-12655","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2026-10-15T17:32:59.205388Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-10-15T19:14:57.983Z"}}]}}}