{"id":"CVE-2026-118458","state":"PUBLISHED","title":"AIS shared test login provider contains fixed administrative credentials","description":"The shared AIS login routing selects a production-shipped test DAO and plaintext comparison for the H and V application codes, accepting fixed administrator accounts.","publishedAt":"2026-11-09T11:46:22.642Z","updatedAt":"2026-11-12T16:03:42.687Z","severity":{"score":8.1,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U","source":"ENISA"},"assigner":"ENISA","products":["CompuGroup Medical Phronesis","CompuGroup Medical Venere"],"affected":[{"vendor":"CompuGroup Medical","product":"Phronesis","packageName":"cgm.it.ais.common","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"5.1.15.1.1","versionType":"semver"}]},{"vendor":"CompuGroup Medical","product":"Venere","packageName":"cgm.it.ais.common","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"5.1.15.1.1","versionType":"semver"}]}],"references":["https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical","https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"],"weaknesses":["CWE-798"],"ingestedAt":"2026-11-12T16:18:06.507Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/118xxx/CVE-2026-118458.json","commit":"49cd4a7173467821e8f2b0c98cb0598f8faf63de","baselineCommit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-118458","state":"PUBLISHED","datePublished":"2026-11-09T11:46:22.642Z","dateUpdated":"2026-11-12T16:03:42.687Z","assignerShortName":"ENISA","assignerOrgId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","dateReserved":"2026-10-28T08:46:23.510Z"},"containers":{"cna":{"title":"AIS shared test login provider contains fixed administrative credentials","descriptions":[{"lang":"en","value":"The shared AIS login routing selects a production-shipped test DAO and plaintext comparison for the H and V application codes, accepting fixed administrator accounts."}],"affected":[{"vendor":"CompuGroup Medical","product":"Phronesis","packageName":"cgm.it.ais.common","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"5.1.15.1.1","versionType":"semver"}]},{"vendor":"CompuGroup Medical","product":"Venere","packageName":"cgm.it.ais.common","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"5.1.15.1.1","versionType":"semver"}]}],"references":[{"url":"https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"},{"url":"https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subAvailabilityImpact":"NONE","exploitMaturity":"UNREPORTED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"HIGH","baseScore":8.1,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-798","lang":"en","description":"CWE-798","type":"CWE"}]}],"providerMetadata":{"shortName":"ENISA","orgId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","dateUpdated":"2026-11-09T11:46:22.642Z"},"credits":[{"lang":"en","value":"Marco Sala","type":"finder"},{"lang":"en","value":"CSIRT-IT","type":"coordinator"},{"lang":"en","value":"ApoCert srl","type":"finder"}],"x_generator":{"engine":"Vulnogram 1.0.5"},"source":{"discovery":"UNKNOWN"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-11-12T16:03:22.542759Z","id":"CVE-2026-118458","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-11-12T16:03:42.687Z"}}]}}}