{"id":"CVE-2026-109618","state":"PUBLISHED","title":"RCE via OOM corruption","description":"PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).","publishedAt":"2026-10-21T13:48:34.845Z","updatedAt":"2026-10-30T18:31:35.583Z","severity":{"score":9.2,"label":"Critical","version":"4.0","vector":"CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"php"},"assigner":"php","products":["PHP Group PHP"],"affected":[{"vendor":"PHP Group","product":"PHP","packageName":"php-src","defaultStatus":"unaffected","versions":[{"version":"8.2.*","status":"affected","lessThan":"8.2.35","versionType":"semver"},{"version":"8.3.*","status":"affected","lessThan":"8.3.36","versionType":"semver"},{"version":"8.4.*","status":"affected","lessThan":"8.4.27","versionType":"semver"},{"version":"8.5.*","status":"affected","lessThan":"8.5.12","versionType":"semver"}]}],"references":["https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w","https://www.wiz.io/blog/php2shell-php-rce","https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/","https://php2shell.delftintellab.com","https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618","http://www.openwall.com/lists/oss-security/2026/10/21/6","http://www.openwall.com/lists/oss-security/2026/10/23/5","http://seclists.org/fulldisclosure/2026/Oct/51","https://cert-portal.siemens.com/productcert/html/ssa-566512.html","https://cert-portal.siemens.com/productcert/html/ssa-566435.html","https://cert-portal.siemens.com/productcert/html/ssa-166980.html"],"weaknesses":["CWE-416","CWE-755","CWE-824","CWE-1325","CWE-1419"],"ingestedAt":"2026-10-30T18:40:06.088Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/109xxx/CVE-2026-109618.json","commit":"7c60edf882a89f07fcce8b786bfad034e7ddeecb","baselineCommit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-109618","state":"PUBLISHED","datePublished":"2026-10-21T13:48:34.845Z","dateUpdated":"2026-10-30T18:31:35.583Z","assignerShortName":"php","assignerOrgId":"dd77f84a-d19a-4638-8c3d-a322d820ed2b","dateReserved":"2026-10-12T21:03:58.117Z"},"containers":{"cna":{"title":"RCE via OOM corruption","descriptions":[{"lang":"en","value":"PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."}],"affected":[{"vendor":"PHP Group","product":"PHP","packageName":"php-src","defaultStatus":"unaffected","versions":[{"version":"8.2.*","status":"affected","lessThan":"8.2.35","versionType":"semver"},{"version":"8.3.*","status":"affected","lessThan":"8.3.36","versionType":"semver"},{"version":"8.4.*","status":"affected","lessThan":"8.4.27","versionType":"semver"},{"version":"8.5.*","status":"affected","lessThan":"8.5.12","versionType":"semver"}]}],"references":[{"url":"https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w","tags":["vendor-advisory"]}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"NETWORK","attackComplexity":"HIGH","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"CRITICAL","baseScore":9.2,"vectorString":"CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-416","lang":"en","description":"CWE-416 Use after free","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-755","lang":"en","description":"CWE-755 Improper Handling of Exceptional Conditions","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-824","lang":"en","description":"CWE-824 Access of uninitialized pointer","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-1325","lang":"en","description":"CWE-1325 Improperly controlled sequential memory allocation","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-1419","lang":"en","description":"CWE-1419 Incorrect Initialization of Resource","type":"CWE"}]}],"providerMetadata":{"shortName":"php","orgId":"dd77f84a-d19a-4638-8c3d-a322d820ed2b","dateUpdated":"2026-10-21T13:48:34.845Z"},"impacts":[{"capecId":"CAPEC-234","descriptions":[{"lang":"en","value":"CAPEC-234 Hijacking a privileged process"}]}],"workarounds":[{"lang":"en","value":"Check the GitHub Security Advisory for mitigation strategies.","supportingMedia":[{"type":"text/html","base64":false,"value":"Check the GitHub Security Advisory for mitigation strategies."}]}],"credits":[{"lang":"en","value":"Ryan at Calif.io","type":"reporter"},{"lang":"en","value":"Wiz","type":"reporter"},{"lang":"en","value":"OpenAI","type":"finder"},{"lang":"en","value":"Arnaud Le Blanc","type":"remediation developer"},{"lang":"en","value":"Ilija Tovilo","type":"remediation developer"},{"lang":"en","value":"Jakub Zelenka","type":"remediation developer"},{"lang":"en","value":"Nora Dossche","type":"remediation developer"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.5"}},"adp":[{"title":"CISA ADP Vulnrichment","references":[{"url":"https://www.wiz.io/blog/php2shell-php-rce","tags":["third-party-advisory"]},{"url":"https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/","tags":["third-party-advisory"]},{"url":"https://php2shell.delftintellab.com","tags":["third-party-advisory"]},{"url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618","tags":["government-resource"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-10-21T00:00:00+00:00","options":[{"Exploitation":"active"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3","id":"CVE-2026-109618"}}},{"other":{"type":"kev","content":{"dateAdded":"2026-10-26","reference":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-10-28T03:55:46.712Z"},"timeline":[{"time":"2026-10-26T00:00:00.000Z","lang":"en","value":"CVE-2026-109618 added to CISA KEV"}]},{"title":"CVE Program Container","references":[{"url":"http://www.openwall.com/lists/oss-security/2026/10/21/6"},{"url":"http://www.openwall.com/lists/oss-security/2026/10/23/5"},{"url":"http://seclists.org/fulldisclosure/2026/Oct/51"}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2026-10-29T06:08:47.615Z"}},{"affected":[{"vendor":"Siemens","product":"AX4","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"CADRA","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Capital","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Designcenter","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Designcenter X","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"DFMExpress","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"HyperLynx","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Insights Hub","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Opcenter Connect Electronics","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Opcenter Connect MOM","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Opcenter Execution Core","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Opcenter Execution Foundation","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Opcenter Execution Pharma","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Opcenter Intelligence","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Opcenter Intra Plant Logistics","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Opcenter Quality","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Opcenter RDnL","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Opcenter X","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"PADS Pro Essentials","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"PADS Pro Student Edition","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"PADS Professional","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"PADS Professional - XCR","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"PADS Standard - XCR","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"PADS Standard & Standard Plus","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Polarion","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"QuadView","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"RUGGEDCOM APE1808","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Simcenter Flomaster","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Simcenter Flux","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Simcenter Simlab","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Solid Edge","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Solid Edge","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Supply Chain Suite","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Teamcenter","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Teamcenter Product Cost Management","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Teamcenter Visualization","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"TestWay","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Valor NPI","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Xcargo","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Xpedition Designer","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Xpedition Enterprise","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Xpedition Enterprise XCR","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Xpedition IC Packaging","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Xpedition Layout Browser","defaultStatus":"unknown","versions":[{"version":"0","status":"unaffected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"AMIS TS","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"blueplanet 360 NX3 M6 WM OD IISX","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"blueplanet 360 NX3 M6 WM OD IISX - S","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Energy Engage V2.0SP9","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Energy Engage V3.1SP1","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Spectrum Power 4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Spectrum Power 4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Spectrum Power 4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Spectrum Power 7","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"Spectrum Power TG","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-566512.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-566435.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-166980.html"}],"providerMetadata":{"shortName":"siemens-SADP","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","dateUpdated":"2026-10-30T18:31:35.583Z"},"x_adpType":"supplier"}]}}}