{"id":"CVE-2026-106087","state":"PUBLISHED","title":"TRO600 contains an arbitrary file read vulnerability. An unauthenticated attacker can exploit this vulnerability to read or download arbitrary files on the affected device, includi","description":"TRO600 contains an arbitrary file read vulnerability. An unauthenticated attacker can exploit this vulnerability to read or download arbitrary files on the affected device, including sensitive configuration files and password data, resulting in the disclosure of sensitive information.","publishedAt":"2026-10-27T11:56:54.738Z","updatedAt":"2026-10-27T11:56:54.738Z","severity":{"score":8.7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","source":"Hitachi Energy"},"assigner":"Hitachi Energy","products":["Hitachi Energy TRO600 Series Firmware"],"affected":[{"vendor":"Hitachi Energy","product":"TRO600 Series Firmware","defaultStatus":"unaffected","versions":[{"version":"9.0.0.0","status":"affected","lessThanOrEqual":"9.1.1.0","versionType":"custom"}]}],"references":["https://publisher.hitachienergy.com/preview?DocumentID=8DBD000224&LanguageCode=en&DocumentPartId=&Action=Launch"],"weaknesses":["CWE-306"],"ingestedAt":"2026-10-29T20:10:23.711Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/106xxx/CVE-2026-106087.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-106087","state":"PUBLISHED","datePublished":"2026-10-27T11:56:54.738Z","dateUpdated":"2026-10-27T11:56:54.738Z","assignerShortName":"Hitachi Energy","assignerOrgId":"e383dce4-0c27-4495-91c4-0db157728d17","dateReserved":"2026-10-06T15:07:06.991Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"TRO600 contains an arbitrary file read vulnerability. An unauthenticated attacker can exploit this vulnerability to read or download arbitrary files on the affected device, including sensitive configuration files and password data, resulting in the disclosure of sensitive information."}],"affected":[{"vendor":"Hitachi Energy","product":"TRO600 Series Firmware","defaultStatus":"unaffected","versions":[{"version":"9.0.0.0","status":"affected","lessThanOrEqual":"9.1.1.0","versionType":"custom"}]}],"references":[{"url":"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000224&LanguageCode=en&DocumentPartId=&Action=Launch"}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"HIGH","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","lang":"en","description":"CWE-306 Missing authentication for critical function","type":"CWE"}]}],"providerMetadata":{"shortName":"Hitachi Energy","orgId":"e383dce4-0c27-4495-91c4-0db157728d17","dateUpdated":"2026-10-27T11:56:54.738Z"},"impacts":[{"capecId":"CAPEC-150","descriptions":[{"lang":"en","value":"CAPEC-150 Collect Data from Common Resource Locations"}]}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.5"}}}}}