{"id":"CVE-2026-10521","state":"PUBLISHED","title":"Authenticated unintended access to critical program parameters","description":"An high privileged remote attacker can access a hidden configuration method, that should not be accessible by any user, to modify critical program parameters. This can result in a total loss of confidentiality, integrity and availability.","publishedAt":"2026-06-23T07:34:10.089Z","updatedAt":"2026-06-23T12:28:12.598Z","severity":{"score":8.6,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"CERTVDE"},"assigner":"CERTVDE","products":["MB connect line mbCONNECT24","MB connect line mymbCONNECT24"],"affected":[{"vendor":"MB connect line","product":"mbCONNECT24","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThan":"2.20.2","versionType":"semver"}]},{"vendor":"MB connect line","product":"mymbCONNECT24","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThan":"2.20.2","versionType":"semver"}]},{"vendor":"MB connect line","product":"mbCONNECT24","defaultStatus":"unaffected","versions":[{"version":"2.20.1","status":"affected"}]},{"vendor":"MB connect line","product":"mymbCONNECT24","defaultStatus":"unaffected","versions":[{"version":"2.20.1","status":"affected"}]}],"references":["https://www.certvde.com/en/advisories/VDE-2026-068/"],"weaknesses":["CWE-425"],"ingestedAt":"2026-10-29T20:10:33.477Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2026/10xxx/CVE-2026-10521.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-10521","state":"PUBLISHED","datePublished":"2026-06-23T07:34:10.089Z","dateUpdated":"2026-06-23T12:28:12.598Z","assignerShortName":"CERTVDE","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateReserved":"2026-06-01T08:47:49.983Z"},"containers":{"cna":{"title":"Authenticated unintended access to critical program parameters","descriptions":[{"lang":"en","value":"An high privileged remote attacker can access a hidden configuration method, that should not be accessible by any user, to modify critical program parameters. This can result in a total loss of confidentiality, integrity and availability."}],"affected":[{"vendor":"MB connect line","product":"mbCONNECT24","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThan":"2.20.2","versionType":"semver"}]},{"vendor":"MB connect line","product":"mymbCONNECT24","defaultStatus":"unaffected","versions":[{"version":"0.0.0","status":"affected","lessThan":"2.20.2","versionType":"semver"}]},{"vendor":"MB connect line","product":"mbCONNECT24","defaultStatus":"unaffected","versions":[{"version":"2.20.1","status":"affected"}]},{"vendor":"MB connect line","product":"mymbCONNECT24","defaultStatus":"unaffected","versions":[{"version":"2.20.1","status":"affected"}]}],"references":[{"url":"https://www.certvde.com/en/advisories/VDE-2026-068/"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.6,"baseSeverity":"HIGH","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-425","description":"CWE-425 Direct Request ('Forced Browsing')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"CERTVDE","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateUpdated":"2026-06-23T07:34:10.089Z"},"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:mb_connect_line:mbconnect24:*:*:*:*:*:*:*:*","versionEndExcluding":"2.20.2","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:mb_connect_line:mymbconnect24:*:*:*:*:*:*:*:*","versionEndExcluding":"2.20.2","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:mb_connect_line:mbconnect24:2.20.1:*:*:*:*:*:*:*","versionStartIncluding":"2.20.1","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:mb_connect_line:mymbconnect24:2.20.1:*:*:*:*:*:*:*","versionStartIncluding":"2.20.1","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"source":{"advisory":"VDE-2026-068","defect":["CERT@VDE#642091"],"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.4.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-06-23T12:28:07.155466Z","id":"CVE-2026-10521","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-06-23T12:28:12.598Z"}}]}}}