{"id":"CVE-2025-7746","state":"PUBLISHED","title":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user ","description":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser.","publishedAt":"2025-09-09T21:02:08.936Z","updatedAt":"2025-11-03T18:14:06.463Z","severity":{"score":5.3,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N","source":"schneider"},"assigner":"schneider","products":["Schneider Electric ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives","Schneider Electric ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives","Schneider Electric ILC992 InterLink Converter","Schneider Electric ATV340E Altivar Machine Drives","Schneider Electric ATV6000 Medium Voltage Altivar Process Drives","Schneider Electric ATS490 Altivar Soft Starter","Schneider Electric VW3A3720 & VW3A3721 Altivar Process Communication Modules","Schneider Electric VW3A3530D: ATVdPAC module"],"affected":[{"vendor":"Schneider Electric","product":"ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"ILC992 InterLink Converter","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"ATV340E Altivar Machine Drives","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"ATV6000 Medium Voltage Altivar Process Drives","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"ATS490 Altivar Soft Starter","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"VW3A3720 & VW3A3721 Altivar Process Communication Modules","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"VW3A3530D: ATVdPAC module","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected","lessThan":"v25.0","versionType":"version"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-252-01.pdf","http://seclists.org/fulldisclosure/2025/Sep/69"],"weaknesses":["CWE-79"],"ingestedAt":"2026-10-29T20:10:04.440Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/7xxx/CVE-2025-7746.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-7746","state":"PUBLISHED","datePublished":"2025-09-09T21:02:08.936Z","dateUpdated":"2025-11-03T18:14:06.463Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2025-07-17T09:10:51.541Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser."}],"affected":[{"vendor":"Schneider Electric","product":"ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"ILC992 InterLink Converter","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"ATV340E Altivar Machine Drives","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"ATV6000 Medium Voltage Altivar Process Drives","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"ATS490 Altivar Soft Starter","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"VW3A3720 & VW3A3721 Altivar Process Communication Modules","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"Schneider Electric","product":"VW3A3530D: ATVdPAC module","defaultStatus":"unaffected","versions":[{"version":"all versions","status":"affected","lessThan":"v25.0","versionType":"version"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-252-01.pdf"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":5.3,"baseSeverity":"MEDIUM","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"LOW","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2025-09-09T21:02:08.936Z"},"datePublic":"2025-09-09T04:01:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-09-10T13:40:20.821038Z","id":"CVE-2025-7746","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-09-10T16:10:34.376Z"}},{"title":"CVE Program Container","references":[{"url":"http://seclists.org/fulldisclosure/2025/Sep/69"}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2025-11-03T18:14:06.463Z"}}]}}}