{"id":"CVE-2025-58582","state":"PUBLISHED","title":"Uncontrolled Resource Consumption via log file","description":"If a user tries to login but the provided credentials are incorrect a log is created. The data for this POST requests is not validated and it’s possible to send giant payloads which are then logged.","publishedAt":"2025-10-06T06:50:56.953Z","updatedAt":"2025-10-06T12:18:15.680Z","severity":{"score":5.3,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","source":"SICK AG"},"assigner":"SICK AG","products":["SICK AG Enterprise Analytics"],"affected":[{"vendor":"SICK AG","product":"Enterprise Analytics","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected","versionType":"custom"}]}],"references":["https://sick.com/psirt","https://www.sick.com/media/docs/9/19/719/special_information_sick_operating_guidelines_cybersecurity_by_sick_en_im0106719.pdf","https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","https://www.first.org/cvss/calculator/3.1","https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0010.json","https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0010.pdf"],"weaknesses":["CWE-770"],"ingestedAt":"2026-10-29T20:09:39.787Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/58xxx/CVE-2025-58582.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-58582","state":"PUBLISHED","datePublished":"2025-10-06T06:50:56.953Z","dateUpdated":"2025-10-06T12:18:15.680Z","assignerShortName":"SICK AG","assignerOrgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateReserved":"2025-09-03T08:58:14.355Z"},"containers":{"cna":{"title":"Uncontrolled Resource Consumption via log file","descriptions":[{"lang":"en","value":"If a user tries to login but the provided credentials are incorrect a log is created. The data for this POST requests is not validated and it’s possible to send giant payloads which are then logged."}],"affected":[{"vendor":"SICK AG","product":"Enterprise Analytics","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected","versionType":"custom"}]}],"references":[{"url":"https://sick.com/psirt","tags":["x_SICK PSIRT Security Advisories"]},{"url":"https://www.sick.com/media/docs/9/19/719/special_information_sick_operating_guidelines_cybersecurity_by_sick_en_im0106719.pdf","tags":["x_SICK Operating Guidelines"]},{"url":"https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","tags":["x_ICS-CERT recommended practices on Industrial Security"]},{"url":"https://www.first.org/cvss/calculator/3.1","tags":["x_CVSS v3.1 Calculator"]},{"url":"https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0010.json","tags":["x_The canonical URL."]},{"url":"https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0010.pdf","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","environmentalScore":5.3,"environmentalSeverity":"MEDIUM","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","temporalScore":5.3,"temporalSeverity":"MEDIUM","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-770","description":"CWE-770 Allocation of Resources Without Limits or Throttling","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"SICK AG","orgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateUpdated":"2025-10-06T07:10:18.707Z"},"source":{"advisory":"SCA-2025-0010","discovery":"INTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.</p>"}],"value":"Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices."}],"x_generator":{"engine":"csaf2cve 0.2.1"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-10-06T12:16:51.621488Z","id":"CVE-2025-58582","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-10-06T12:18:15.680Z"}}]}}}