{"id":"CVE-2025-50122","state":"PUBLISHED","title":"A CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the","description":"A CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the\npassword generation algorithm is reverse engineered with access to installation or upgrade artifacts.","publishedAt":"2025-07-11T09:17:19.014Z","updatedAt":"2025-11-03T20:05:36.663Z","severity":{"score":8.9,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H","source":"schneider"},"assigner":"schneider","products":["Schneider Electric EcoStruxure™ IT Data Center Expert"],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure™ IT Data Center Expert","defaultStatus":"unaffected","versions":[{"version":"8.3","status":"affected","lessThanOrEqual":"Prior to","versionType":"custom"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-189-01.pdf","http://seclists.org/fulldisclosure/2025/Jul/7"],"weaknesses":["CWE-331"],"ingestedAt":"2026-10-29T20:09:23.771Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/50xxx/CVE-2025-50122.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-50122","state":"PUBLISHED","datePublished":"2025-07-11T09:17:19.014Z","dateUpdated":"2025-11-03T20:05:36.663Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2025-06-12T13:53:23.603Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the\npassword generation algorithm is reverse engineered with access to installation or upgrade artifacts."}],"affected":[{"vendor":"Schneider Electric","product":"EcoStruxure™ IT Data Center Expert","defaultStatus":"unaffected","versions":[{"version":"8.3","status":"affected","lessThanOrEqual":"Prior to","versionType":"custom"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-189-01.pdf"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"HIGH","attackRequirements":"NONE","attackVector":"ADJACENT","baseScore":8.9,"baseSeverity":"HIGH","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"LOW","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-331","description":"CWE-331 Insufficient Entropy","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2025-07-13T23:30:21.080Z"},"datePublic":"2025-07-08T05:00:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-07-11T15:08:21.649572Z","id":"CVE-2025-50122","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-07-11T15:08:35.117Z"}},{"title":"CVE Program Container","references":[{"url":"http://seclists.org/fulldisclosure/2025/Jul/7"}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2025-11-03T20:05:36.663Z"}}]}}}