{"id":"CVE-2025-49196","state":"PUBLISHED","title":"Deprecated TLS version supported","description":"A service supports the use of a deprecated and unsafe TLS version. This could be exploited to expose sensitive information, modify data in unexpected ways or spoof identities of other users or devices, affecting the confidentiality and integrity of the device.","publishedAt":"2025-06-12T14:20:53.321Z","updatedAt":"2025-06-17T19:03:56.791Z","severity":{"score":6.5,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N","source":"SICK AG"},"assigner":"SICK AG","products":["SICK AG SICK Field Analytics"],"affected":[{"vendor":"SICK AG","product":"SICK Field Analytics","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected","versionType":"custom"}]}],"references":["https://sick.com/psirt","https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF","https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","https://www.first.org/cvss/calculator/3.1","https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0007.pdf","https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0007.json"],"weaknesses":["CWE-327"],"ingestedAt":"2026-10-29T20:09:23.771Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/49xxx/CVE-2025-49196.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-49196","state":"PUBLISHED","datePublished":"2025-06-12T14:20:53.321Z","dateUpdated":"2025-06-17T19:03:56.791Z","assignerShortName":"SICK AG","assignerOrgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateReserved":"2025-06-03T05:58:15.616Z"},"containers":{"cna":{"title":"Deprecated TLS version supported","descriptions":[{"lang":"en","value":"A service supports the use of a deprecated and unsafe TLS version. This could be exploited to expose sensitive information, modify data in unexpected ways or spoof identities of other users or devices, affecting the confidentiality and integrity of the device."}],"affected":[{"vendor":"SICK AG","product":"SICK Field Analytics","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected","versionType":"custom"}]}],"references":[{"url":"https://sick.com/psirt","tags":["x_SICK PSIRT Website"]},{"url":"https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF","tags":["x_SICK Operating Guidelines"]},{"url":"https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","tags":["x_ICS-CERT recommended practices on Industrial Security"]},{"url":"https://www.first.org/cvss/calculator/3.1","tags":["x_CVSS v3.1 Calculator"]},{"url":"https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0007.pdf","tags":["vendor-advisory"]},{"url":"https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0007.json","tags":["vendor-advisory","x_csaf"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-327","description":"CWE-327 Use of a Broken or Risky Cryptographic Algorithm","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"SICK AG","orgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateUpdated":"2025-06-13T06:17:26.069Z"},"source":{"advisory":"sca-2025-0007","discovery":"INTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<code>Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \\\"SICK Operating Guidelines\\\" and \\\"ICS-CERT recommended practices on Industrial Security\\\" could help to implement the general security practices.</code>"}],"value":"Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \\\"SICK Operating Guidelines\\\" and \\\"ICS-CERT recommended practices on Industrial Security\\\" could help to implement the general security practices."}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-06-12T14:38:45.930361Z","id":"CVE-2025-49196","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-06-17T19:03:56.791Z"}}]}}}