{"id":"CVE-2025-49191","state":"PUBLISHED","title":"Dashboards and iFrames can link malicious web content","description":"Linked URLs during the creation of iFrame widgets and dashboards are vulnerable to code execution. The URLs get embedded as iFrame widgets, making it possible to attack other users that access the dashboard by including malicious code. The attack is only possible if the attacker is authorized to create new dashboards or iFrame widgets.","publishedAt":"2025-06-12T14:08:02.756Z","updatedAt":"2025-06-12T14:12:22.866Z","severity":{"score":4.8,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N","source":"SICK AG"},"assigner":"SICK AG","products":["SICK AG SICK Field Analytics"],"affected":[{"vendor":"SICK AG","product":"SICK Field Analytics","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected","versionType":"custom"}]}],"references":["https://sick.com/psirt","https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF","https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","https://www.first.org/cvss/calculator/3.1","https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0007.pdf","https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0007.json"],"weaknesses":["CWE-1021"],"ingestedAt":"2026-10-29T20:09:23.771Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/49xxx/CVE-2025-49191.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-49191","state":"PUBLISHED","datePublished":"2025-06-12T14:08:02.756Z","dateUpdated":"2025-06-12T14:12:22.866Z","assignerShortName":"SICK AG","assignerOrgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateReserved":"2025-06-03T05:58:15.615Z"},"containers":{"cna":{"title":"Dashboards and iFrames can link malicious web content","descriptions":[{"lang":"en","value":"Linked URLs during the creation of iFrame widgets and dashboards are vulnerable to code execution. The URLs get embedded as iFrame widgets, making it possible to attack other users that access the dashboard by including malicious code. The attack is only possible if the attacker is authorized to create new dashboards or iFrame widgets."}],"affected":[{"vendor":"SICK AG","product":"SICK Field Analytics","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected","versionType":"custom"}]}],"references":[{"url":"https://sick.com/psirt","tags":["x_SICK PSIRT Website"]},{"url":"https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF","tags":["x_SICK Operating Guidelines"]},{"url":"https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","tags":["x_ICS-CERT recommended practices on Industrial Security"]},{"url":"https://www.first.org/cvss/calculator/3.1","tags":["x_CVSS v3.1 Calculator"]},{"url":"https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0007.pdf","tags":["vendor-advisory"]},{"url":"https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0007.json","tags":["vendor-advisory","x_csaf"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.8,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"HIGH","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1021","description":"CWE-1021 Improper Restriction of Rendered UI Layers or Frames","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"SICK AG","orgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateUpdated":"2025-06-12T14:08:02.756Z"},"source":{"advisory":"sca-2025-0007","discovery":"INTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<code>Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \\\"SICK Operating Guidelines\\\" and \\\"ICS-CERT recommended practices on Industrial Security\\\" could help to implement the general security practices.</code>"}],"value":"Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \\\"SICK Operating Guidelines\\\" and \\\"ICS-CERT recommended practices on Industrial Security\\\" could help to implement the general security practices."}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-06-12T14:12:08.495610Z","id":"CVE-2025-49191","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-06-12T14:12:22.866Z"}}]}}}