{"id":"CVE-2025-47418","state":"PUBLISHED","title":"Recording","description":"Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.\n\nThere is no visible indication when the system is recording and recording can be enabled remotely via a network API. \nThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.","publishedAt":"2025-05-06T20:13:38.805Z","updatedAt":"2025-05-07T14:04:11.178Z","severity":{"score":5.3,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","source":"Crestron"},"assigner":"Crestron","products":["Crestron Automate VX"],"affected":[{"vendor":"Crestron","product":"Automate VX","defaultStatus":"unaffected","versions":[{"version":"5.6.8161.21536","status":"affected","lessThanOrEqual":"6.4.0.49","changes":[{"at":"6.4.1.8","status":"unaffected"}],"versionType":"custom"}]}],"references":["https://security.crestron.com/","https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8","https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf"],"weaknesses":["CWE-200"],"ingestedAt":"2026-10-29T20:09:23.771Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/47xxx/CVE-2025-47418.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-47418","state":"PUBLISHED","datePublished":"2025-05-06T20:13:38.805Z","dateUpdated":"2025-05-07T14:04:11.178Z","assignerShortName":"Crestron","assignerOrgId":"25b0b659-c4b4-483f-aecb-067757d23ef3","dateReserved":"2025-05-06T19:36:18.441Z"},"containers":{"cna":{"title":"Recording","descriptions":[{"lang":"en","value":"Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.\n\nThere is no visible indication when the system is recording and recording can be enabled remotely via a network API. \nThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49."}],"affected":[{"vendor":"Crestron","product":"Automate VX","defaultStatus":"unaffected","versions":[{"version":"5.6.8161.21536","status":"affected","lessThanOrEqual":"6.4.0.49","changes":[{"at":"6.4.1.8","status":"unaffected"}],"versionType":"custom"}]}],"references":[{"url":"https://security.crestron.com/","tags":["vendor-advisory"]},{"url":"https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8"},{"url":"https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf","tags":["release-notes"]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":5.3,"baseSeverity":"MEDIUM","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-200","description":"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Crestron","orgId":"25b0b659-c4b4-483f-aecb-067757d23ef3","dateUpdated":"2025-05-06T20:20:24.812Z"},"credits":[{"lang":"en","type":"finder","value":"Crestron Electronics Inc"}],"datePublic":"2025-04-23T20:04:00.000Z","impacts":[{"capecId":"CAPEC-212","descriptions":[{"lang":"en","value":"CAPEC-212 Functionality Misuse"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">Crestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will&nbsp;</span><span style=\"background-color: rgb(255, 255, 255);\">adds </span><span style=\"background-color: rgb(255, 255, 255);\">a</span><span style=\"background-color: rgb(255, 255, 255);\"> visual</span> <span style=\"background-color: rgb(255, 255, 255);\">indication</span> <span style=\"background-color: rgb(255, 255, 255);\">on </span><span style=\"background-color: rgb(255, 255, 255);\">the program </span><span style=\"background-color: rgb(255, 255, 255);\">video output </span><span style=\"background-color: rgb(255, 255, 255);\">when recording is </span><span style=\"background-color: rgb(255, 255, 255);\">started</span><span style=\"background-color: rgb(255, 255, 255);\">.</span><span style=\"background-color: rgb(255, 255, 255);\">&nbsp;&nbsp;</span><br>"}],"value":"Crestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will adds a visual indication on the program video output when recording is started."}],"source":{"discovery":"INTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">Inform users in the room that they may be recorded. Also, configure the network to only allow needed systems and/or devices to access the API.</span><span style=\"background-color: rgb(255, 255, 255);\">&nbsp;</span>\n\n<br>"}],"value":"Inform users in the room that they may be recorded. Also, configure the network to only allow needed systems and/or devices to access the API."}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-05-07T13:46:13.710646Z","id":"CVE-2025-47418","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-05-07T14:04:11.178Z"}}]}}}