{"id":"CVE-2025-44526","state":"PUBLISHED","title":"Realtek RTL8762EKF-EVB RTL8762E SDK V1.4.0 was discovered to utilize insufficient permission checks on critical fields within Bluetooth Low Energy (BLE) data packets. This issue al","description":"Realtek RTL8762EKF-EVB RTL8762E SDK V1.4.0 was discovered to utilize insufficient permission checks on critical fields within Bluetooth Low Energy (BLE) data packets. This issue allows attackers to cause a Denial of Service (DoS) via a crafted LL_Length_Req packet.","publishedAt":"2025-07-09T00:00:00.000Z","updatedAt":"2026-07-05T16:06:32.768Z","severity":{"score":6.5,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","source":"CISA-ADP"},"assigner":"mitre","products":["n/a n/a"],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":["https://github.com/yangting111/BLE_TEST/blob/main/result/PoC/Realtek/Improper_Validation_of_BLE_PDU_Length.md"],"weaknesses":["CWE-284","CWE-20"],"ingestedAt":"2026-10-29T20:09:17.366Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/44xxx/CVE-2025-44526.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-44526","state":"PUBLISHED","datePublished":"2025-07-09T00:00:00.000Z","dateUpdated":"2026-07-05T16:06:32.768Z","assignerShortName":"mitre","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","dateReserved":"2025-04-22T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Realtek RTL8762EKF-EVB RTL8762E SDK V1.4.0 was discovered to utilize insufficient permission checks on critical fields within Bluetooth Low Energy (BLE) data packets. This issue allows attackers to cause a Denial of Service (DoS) via a crafted LL_Length_Req packet."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"https://github.com/yangting111/BLE_TEST/blob/main/result/PoC/Realtek/Improper_Validation_of_BLE_PDU_Length.md"}],"problemTypes":[{"descriptions":[{"type":"text","lang":"en","description":"n/a"}]}],"providerMetadata":{"shortName":"mitre","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","dateUpdated":"2026-07-05T16:06:32.768Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":6.5,"attackVector":"ADJACENT_NETWORK","baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","integrityImpact":"NONE","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"NONE"}},{"other":{"type":"ssvc","content":{"timestamp":"2025-07-09T19:40:37.603788Z","id":"CVE-2025-44526","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-284","type":"CWE","lang":"en","description":"CWE-284 Improper Access Control"}]},{"descriptions":[{"cweId":"CWE-20","type":"CWE","lang":"en","description":"CWE-20 Improper Input Validation"}]}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-07-09T19:42:34.487Z"}}]}}}