{"id":"CVE-2025-43888","state":"PUBLISHED","title":"Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with lo","description":"Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access.","publishedAt":"2025-09-10T15:42:34.448Z","updatedAt":"2026-02-26T17:48:44.642Z","severity":{"score":8.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","source":"dell"},"assigner":"dell","products":["Dell PowerProtect Data Manager"],"affected":[{"vendor":"Dell","product":"PowerProtect Data Manager","defaultStatus":"unaffected","versions":[{"version":"N/A","status":"affected","lessThan":"19.21 build 11","versionType":"semver"}]}],"references":["https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"],"weaknesses":["CWE-532"],"ingestedAt":"2026-10-29T20:09:17.366Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/43xxx/CVE-2025-43888.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-43888","state":"PUBLISHED","datePublished":"2025-09-10T15:42:34.448Z","dateUpdated":"2026-02-26T17:48:44.642Z","assignerShortName":"dell","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateReserved":"2025-04-18T05:05:05.741Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."}],"affected":[{"vendor":"Dell","product":"PowerProtect Data Manager","defaultStatus":"unaffected","versions":[{"version":"N/A","status":"affected","lessThan":"19.21 build 11","versionType":"semver"}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities","tags":["vendor-advisory"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-532","description":"CWE-532: Insertion of Sensitive Information into Log File","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"dell","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateUpdated":"2025-09-10T15:43:08.746Z"},"datePublic":"2025-09-09T17:00:00.000Z","source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2025-43888","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2025-09-11T03:56:26.040843Z"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-02-26T17:48:44.642Z"}}]}}}