{"id":"CVE-2025-41738","state":"PUBLISHED","title":"CODESYS Control - Invalid type usage in visualization","description":"An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.","publishedAt":"2025-12-01T10:02:33.407Z","updatedAt":"2025-12-01T14:00:28.509Z","severity":{"score":7.5,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","source":"CERTVDE"},"assigner":"CERTVDE","products":["CODESYS CODESYS Control RTE (SL)","CODESYS CODESYS Control RTE (for Beckhoff CX) SL","CODESYS CODESYS Control Win (SL)","CODESYS CODESYS HMI (SL)","CODESYS CODESYS Remote Target Visu","CODESYS CODESYS Runtime Toolkit","CODESYS CODESYS Control for BeagleBone SL","CODESYS CODESYS Control for emPC-A/iMX6 SL","CODESYS CODESYS Control for IOT2000 SL","CODESYS CODESYS Control for Linux ARM SL","CODESYS CODESYS Control for Linux SL","CODESYS CODESYS Control for PFC100 SL","CODESYS CODESYS Control for PFC200 SL","CODESYS CODESYS Control for PLCnext SL","CODESYS CODESYS Control for Raspberry Pi SL","CODESYS CODESYS Control for WAGO Touch Panels 600 SL","CODESYS CODESYS Virtual Control SL"],"affected":[{"vendor":"CODESYS","product":"CODESYS Control RTE (SL)","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (for Beckhoff CX) SL","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control Win (SL)","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS HMI (SL)","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Remote Target Visu","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Runtime Toolkit","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for BeagleBone SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for emPC-A/iMX6 SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for IOT2000 SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux ARM SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC100 SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC200 SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PLCnext SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Raspberry Pi SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for WAGO Touch Panels 600 SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Virtual Control SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]}],"references":["https://certvde.com/de/advisories/VDE-2025-100"],"weaknesses":["CWE-843"],"ingestedAt":"2026-10-29T20:09:09.358Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/41xxx/CVE-2025-41738.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-41738","state":"PUBLISHED","datePublished":"2025-12-01T10:02:33.407Z","dateUpdated":"2025-12-01T14:00:28.509Z","assignerShortName":"CERTVDE","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateReserved":"2025-04-16T11:17:48.320Z"},"containers":{"cna":{"title":"CODESYS Control - Invalid type usage in visualization","descriptions":[{"lang":"en","value":"An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition."}],"affected":[{"vendor":"CODESYS","product":"CODESYS Control RTE (SL)","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control RTE (for Beckhoff CX) SL","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control Win (SL)","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS HMI (SL)","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Remote Target Visu","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Runtime Toolkit","defaultStatus":"unaffected","versions":[{"version":"3.5.18.0","status":"affected","lessThan":"3.5.21.40","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for BeagleBone SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for emPC-A/iMX6 SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for IOT2000 SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux ARM SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Linux SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC100 SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PFC200 SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for PLCnext SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for Raspberry Pi SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Control for WAGO Touch Panels 600 SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]},{"vendor":"CODESYS","product":"CODESYS Virtual Control SL","defaultStatus":"unaffected","versions":[{"version":"4.5.0.0","status":"affected","lessThan":"4.19.0.0","versionType":"semver"}]}],"references":[{"url":"https://certvde.com/de/advisories/VDE-2025-100"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-843","description":"CWE-843 Access of Resource Using Incompatible Type ('Type Confusion')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"CERTVDE","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","dateUpdated":"2025-12-01T10:02:33.407Z"},"source":{"advisory":"VDE-2025-100","defect":["CERT@VDE#641889"],"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-12-01T13:59:44.375519Z","id":"CVE-2025-41738","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-12-01T14:00:28.509Z"}}]}}}