{"id":"CVE-2025-40894","state":"PUBLISHED","title":"HTML injection in Alerted Nodes Dashboard in Guardian/CMC before 25.6.0","description":"A Stored HTML Injection vulnerability was discovered in the Alerted Nodes Dashboard functionality due to improper validation on an input parameter.\n\n\n\nA malicious authenticated user with the required privileges could edit a node label to inject HTML tags. If the system is configured to use the Alerted Nodes Dashboard, and alerts are reported for the affected node, then the injected HTML may render in the browser of a victim user interacting with it, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.","publishedAt":"2026-03-04T13:51:14.413Z","updatedAt":"2026-08-11T12:22:53.872Z","severity":{"score":2.1,"label":"Low","version":"4.0","vector":"CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N","source":"Nozomi"},"assigner":"Nozomi","products":["Nozomi Networks Guardian","Nozomi Networks CMC"],"affected":[{"vendor":"Nozomi Networks","product":"Guardian","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"25.6.0","versionType":"semver"}]},{"vendor":"Nozomi Networks","product":"CMC","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"25.6.0","versionType":"semver"}]}],"references":["https://security.nozominetworks.com/NN-2025:16-01","https://cert-portal.siemens.com/productcert/html/ssa-827968.html"],"weaknesses":["CWE-79"],"ingestedAt":"2026-10-29T20:09:09.358Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/40xxx/CVE-2025-40894.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-40894","state":"PUBLISHED","datePublished":"2026-03-04T13:51:14.413Z","dateUpdated":"2026-08-11T12:22:53.872Z","assignerShortName":"Nozomi","assignerOrgId":"bec8025f-a851-46e5-b3a3-058e6b0aa23c","dateReserved":"2025-04-16T09:04:25.007Z"},"containers":{"cna":{"title":"HTML injection in Alerted Nodes Dashboard in Guardian/CMC before 25.6.0","descriptions":[{"lang":"en","value":"A Stored HTML Injection vulnerability was discovered in the Alerted Nodes Dashboard functionality due to improper validation on an input parameter.\n\n\n\nA malicious authenticated user with the required privileges could edit a node label to inject HTML tags. If the system is configured to use the Alerted Nodes Dashboard, and alerts are reported for the affected node, then the injected HTML may render in the browser of a victim user interacting with it, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."}],"affected":[{"vendor":"Nozomi Networks","product":"Guardian","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"25.6.0","versionType":"semver"}]},{"vendor":"Nozomi Networks","product":"CMC","defaultStatus":"unaffected","versions":[{"version":"0","status":"affected","lessThan":"25.6.0","versionType":"semver"}]}],"references":[{"url":"https://security.nozominetworks.com/NN-2025:16-01"}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"HIGH","attackRequirements":"PRESENT","attackVector":"NETWORK","baseScore":2.1,"baseSeverity":"LOW","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"LOW","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.4,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Nozomi","orgId":"bec8025f-a851-46e5-b3a3-058e6b0aa23c","dateUpdated":"2026-03-04T13:51:14.413Z"},"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*","versionEndExcluding":"25.6.0","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*","versionEndExcluding":"25.6.0","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"credits":[{"lang":"en","type":"finder","value":"This issue was found by Stefano Libero of Nozomi Networks Product Security team during an internal investigation."}],"datePublic":"2026-03-04T08:00:00.000Z","impacts":[{"capecId":"CAPEC-592","descriptions":[{"lang":"en","value":"CAPEC-592 Stored XSS"}]}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<div><div>Upgrade to v25.6.0 or later.</div></div>"}],"value":"Upgrade to v25.6.0 or later."}],"source":{"discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-03-04T14:18:33.627989Z","id":"CVE-2025-40894","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2026-03-04T14:18:40.821Z"}},{"affected":[{"vendor":"Siemens","product":"RUGGEDCOM APE1808","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-827968.html"}],"providerMetadata":{"shortName":"siemens-SADP","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","dateUpdated":"2026-08-11T12:22:53.872Z"},"x_adpType":"supplier"}]}}}