{"id":"CVE-2025-40766","state":"PUBLISHED","title":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application runs docker containers without adequate resource ","description":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application runs docker containers without adequate resource and security limitations. This could allow an attacker to perform a denial-of-service (DoS) attack.","publishedAt":"2025-08-12T11:17:15.998Z","updatedAt":"2025-08-12T14:27:06.522Z","severity":{"score":6.8,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens SINEC Traffic Analyzer"],"affected":[{"vendor":"Siemens","product":"SINEC Traffic Analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-517338.html"],"weaknesses":["CWE-400"],"ingestedAt":"2026-10-29T20:09:09.358Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/40xxx/CVE-2025-40766.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-40766","state":"PUBLISHED","datePublished":"2025-08-12T11:17:15.998Z","dateUpdated":"2025-08-12T14:27:06.522Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2025-04-16T08:39:30.032Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application runs docker containers without adequate resource and security limitations. This could allow an attacker to perform a denial-of-service (DoS) attack."}],"affected":[{"vendor":"Siemens","product":"SINEC Traffic Analyzer","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V3.0","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-517338.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","baseScore":5.5,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","baseScore":6.8,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-400","lang":"en","description":"CWE-400: Uncontrolled Resource Consumption","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2025-08-12T11:17:15.998Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-08-12T14:26:55.715668Z","id":"CVE-2025-40766","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-08-12T14:27:06.522Z"}}]}}}