{"id":"CVE-2025-40584","state":"PUBLISHED","title":"A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTI","description":"A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions < V5.7 SP1 HF1), SIMOTION SCOUT V5.4 (All versions), SIMOTION SCOUT V5.5 (All versions), SIMOTION SCOUT V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT V5.7 (All versions < V5.7 SP1 HF1), SINAMICS STARTER V5.5 (All versions), SINAMICS STARTER V5.6 (All versions), SINAMICS STARTER V5.7 (All versions < V5.7 HF2). The affected application contains a XML External Entity Injection (XXE) vulnerability while parsing specially crafted XML files. This could allow an attacker to read arbitrary files in the system.","publishedAt":"2025-08-12T11:17:02.605Z","updatedAt":"2025-10-14T09:15:12.695Z","severity":{"score":6.8,"label":"Medium","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","source":"siemens"},"assigner":"siemens","products":["Siemens SIMOTION SCOUT TIA V5.4","Siemens SIMOTION SCOUT TIA V5.5","Siemens SIMOTION SCOUT TIA V5.6","Siemens SIMOTION SCOUT TIA V5.7","Siemens SIMOTION SCOUT V5.4","Siemens SIMOTION SCOUT V5.5","Siemens SIMOTION SCOUT V5.6","Siemens SIMOTION SCOUT V5.7","Siemens SINAMICS STARTER V5.5","Siemens SINAMICS STARTER V5.6","Siemens SINAMICS STARTER V5.7"],"affected":[{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.6","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.6 SP1 HF7","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.7","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.7 SP1 HF1","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.6","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.6 SP1 HF7","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.7","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.7 SP1 HF1","versionType":"custom"}]},{"vendor":"Siemens","product":"SINAMICS STARTER V5.5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SINAMICS STARTER V5.6","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SINAMICS STARTER V5.7","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.7 HF2","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/html/ssa-186293.html"],"weaknesses":["CWE-611"],"ingestedAt":"2026-10-29T20:09:09.358Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/40xxx/CVE-2025-40584.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-40584","state":"PUBLISHED","datePublished":"2025-08-12T11:17:02.605Z","dateUpdated":"2025-10-14T09:15:12.695Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2025-04-16T08:20:17.033Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions < V5.7 SP1 HF1), SIMOTION SCOUT V5.4 (All versions), SIMOTION SCOUT V5.5 (All versions), SIMOTION SCOUT V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT V5.7 (All versions < V5.7 SP1 HF1), SINAMICS STARTER V5.5 (All versions), SINAMICS STARTER V5.6 (All versions), SINAMICS STARTER V5.7 (All versions < V5.7 HF2). The affected application contains a XML External Entity Injection (XXE) vulnerability while parsing specially crafted XML files. This could allow an attacker to read arbitrary files in the system."}],"affected":[{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.6","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.6 SP1 HF7","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.7","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.7 SP1 HF1","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.4","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.6","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.6 SP1 HF7","versionType":"custom"}]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.7","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.7 SP1 HF1","versionType":"custom"}]},{"vendor":"Siemens","product":"SINAMICS STARTER V5.5","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SINAMICS STARTER V5.6","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SINAMICS STARTER V5.7","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V5.7 HF2","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-186293.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","baseScore":5.5,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","baseScore":6.8,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-611","lang":"en","description":"CWE-611: Improper Restriction of XML External Entity Reference","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2025-10-14T09:15:12.695Z"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-08-12T13:30:27.626406Z","id":"CVE-2025-40584","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-08-13T20:18:57.094Z"}}]}}}