{"id":"CVE-2025-3606","state":"PUBLISHED","title":"Vestel AC Charger Exposure of Sensitive System Information to an Unauthorized Control Sphere","description":"Vestel AC Charger \nversion \n\n3.75.0 contains a vulnerability that \ncould enable an attacker to access files containing sensitive \ninformation, such as credentials which could be used to further \ncompromise the device.","publishedAt":"2025-04-24T23:15:52.975Z","updatedAt":"2025-04-25T16:02:38.056Z","severity":{"score":8.7,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","source":"icscert"},"assigner":"icscert","products":["Vestel AC Charger EVC04"],"affected":[{"vendor":"Vestel","product":"AC Charger EVC04","defaultStatus":"unaffected","versions":[{"version":"3.75.0","status":"affected"}]}],"references":["https://www.cisa.gov/news-events/ics-advisories/icsa-25-114-03","https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F1%2FVSA-1_R2.pdf?alt=media&token=8201f299-5014-4720-9200-f1b335736ac1"],"weaknesses":["CWE-497"],"ingestedAt":"2026-10-29T20:09:09.358Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/3xxx/CVE-2025-3606.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-3606","state":"PUBLISHED","datePublished":"2025-04-24T23:15:52.975Z","dateUpdated":"2025-04-25T16:02:38.056Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2025-04-14T19:44:14.176Z"},"containers":{"cna":{"title":"Vestel AC Charger Exposure of Sensitive System Information to an Unauthorized Control Sphere","descriptions":[{"lang":"en","value":"Vestel AC Charger \nversion \n\n3.75.0 contains a vulnerability that \ncould enable an attacker to access files containing sensitive \ninformation, such as credentials which could be used to further \ncompromise the device."}],"affected":[{"vendor":"Vestel","product":"AC Charger EVC04","defaultStatus":"unaffected","versions":[{"version":"3.75.0","status":"affected"}]}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-114-03"},{"url":"https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F1%2FVSA-1_R2.pdf?alt=media&token=8201f299-5014-4720-9200-f1b335736ac1"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-497","description":"CWE-497","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateUpdated":"2025-04-24T23:15:52.975Z"},"credits":[{"lang":"en","type":"finder","value":"Cumhur Kizilari reported this vulnerability to CISA."}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Vestel strongly suggests that users of the related AC chargers update to version V3.187 or a higher version.<br>"}],"value":"Vestel strongly suggests that users of the related AC chargers update to version V3.187 or a higher version."}],"source":{"advisory":"ICSA-25-114-03","discovery":"EXTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Avoid using open network:</p>\n<ul>\n<li>Use secure methods like virtual private networks (VPNs) for remote \naccess. Regularly update VPNs to their latest versions and ensure that \nconnected devices maintain strong security measures.</li>\n<li>Reduce network exposure for applications and endpoints. Only make \nthem accessible via the Internet if specifically designed for and \nrequired by their intended use.</li>\n</ul>\n<p>Login Credentials Management:</p>\n<ul>\n<li>Force end user to revise the factory default set username and password of webconfig page.</li>\n<li>Remove any printed documents such as installation guide, instruction\n book, quick start guide from web where login credentials are featured.</li>\n</ul>\n<p>Please refer to Vestel's <a target=\"_blank\" rel=\"nofollow\" href=\"https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F1%2FVSA-1_R2.pdf?alt=media&amp;token=8201f299-5014-4720-9200-f1b335736ac1\">advisory</a> for more information.\n\n<br></p>"}],"value":"Avoid using open network:\n\n\n\n  *  Use secure methods like virtual private networks (VPNs) for remote \naccess. Regularly update VPNs to their latest versions and ensure that \nconnected devices maintain strong security measures.\n\n  *  Reduce network exposure for applications and endpoints. Only make \nthem accessible via the Internet if specifically designed for and \nrequired by their intended use.\n\n\n\n\nLogin Credentials Management:\n\n\n\n  *  Force end user to revise the factory default set username and password of webconfig page.\n\n  *  Remove any printed documents such as installation guide, instruction\n book, quick start guide from web where login credentials are featured.\n\n\n\n\nPlease refer to Vestel's  advisory https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F1%2FVSA-1_R2.pdf  for more information."}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-25T15:37:27.258163Z","id":"CVE-2025-3606","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-25T16:02:38.056Z"}}]}}}