{"id":"CVE-2025-32470","state":"PUBLISHED","title":"Unauthenticated change of IP adress","description":"A remote unauthenticated attacker may be able to change the IP adress of the device, and therefore affecting the availability of the device.","publishedAt":"2025-04-28T09:07:02.830Z","updatedAt":"2025-04-28T15:45:46.363Z","severity":{"score":7.5,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","source":"SICK AG"},"assigner":"SICK AG","products":["SICK AG SICK FLX0-GPNT100","SICK AG SICK FLX3-CPUC200"],"affected":[{"vendor":"SICK AG","product":"SICK FLX0-GPNT100","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"SICK AG","product":"SICK FLX3-CPUC200","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected"}]}],"references":["https://sick.com/psirt","https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF","https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","https://www.first.org/cvss/calculator/3.1","https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0005.pdf","https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0005.json"],"weaknesses":["CWE-284"],"ingestedAt":"2026-10-29T20:08:55.257Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2025/32xxx/CVE-2025-32470.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-32470","state":"PUBLISHED","datePublished":"2025-04-28T09:07:02.830Z","dateUpdated":"2025-04-28T15:45:46.363Z","assignerShortName":"SICK AG","assignerOrgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateReserved":"2025-04-09T07:42:18.369Z"},"containers":{"cna":{"title":"Unauthenticated change of IP adress","descriptions":[{"lang":"en","value":"A remote unauthenticated attacker may be able to change the IP adress of the device, and therefore affecting the availability of the device."}],"affected":[{"vendor":"SICK AG","product":"SICK FLX0-GPNT100","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected"}]},{"vendor":"SICK AG","product":"SICK FLX3-CPUC200","defaultStatus":"affected","versions":[{"version":"all versions","status":"affected"}]}],"references":[{"url":"https://sick.com/psirt","tags":["x_SICK PSIRT Website"]},{"url":"https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF","tags":["x_SICK Operating Guidelines"]},{"url":"https://www.cisa.gov/resources-tools/resources/ics-recommended-practices","tags":["x_ICS-CERT"]},{"url":"https://www.first.org/cvss/calculator/3.1","tags":["x_CVSS v3.1 Calculator"]},{"url":"https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0005.pdf","tags":["vendor-advisory"]},{"url":"https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0005.json","tags":["vendor-advisory","x_csaf"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-284","description":"CWE-284 (Improper Access Control)","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"SICK AG","orgId":"a6863dd2-93fc-443d-bef1-79f0b5020988","dateUpdated":"2025-04-28T09:07:02.830Z"},"datePublic":"2025-04-28T08:49:00.000Z","source":{"advisory":"SCA-2025-0005","discovery":"INTERNAL"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.<br>"}],"value":"Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices."}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-04-28T15:41:57.691647Z","id":"CVE-2025-32470","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-04-28T15:45:46.363Z"}}]}}}